MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/ajpregu.00096.2026

Медицинская библиотека · American journal of physiology. Regulatory, integrative and comparative physiology · 2026

Phase-dependent autonomic responses to electric fan use during a prolonged 8-h heat exposure in older adults.

Carrillo Andres E, O'Connor Fergus K, Cuza-Berry Meghan N, Herry Christophe L, Seely Andrew J E, McCormick James J, Kenny Glen P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Electric fans are commonly recommended for older adults to reduce heat strain, yet their effects on cardiac autonomic regulation during heat exposure remain unclear. This study examined phase-dependent heart rate variability (HRV) responses to fan use during prolonged heat exposure in older adults. Sixteen participants (6 females; 65-85 yr) completed three 8-h heat exposures (36°C, 45% relative humidity) with fan-generated air speeds of 0, 2, or 4 m/s. Core (rectal) temperature and a 3-lead electrocardiogram were continuously acquired. Based on temporal core temperature responses, heat exposure was divided into Initial Ramp-Up Phase (0-4 h) and Plateau Phase (4-8 h). Core temperature increased from 37.1 (0.3)°C to 38.0 (0.3)°C (P < 0.001) during Ramp-Up and remained stable at 38.1 (0.3)°C (P ≥ 0.627) during Plateau Phase. During Ramp-Up, in all conditions, heart rate (HR) increased (P < 0.001), whereas vagally mediated HRV indices including root mean square of successive differences (RMSSD), high-frequency power, and cardiac vagal index (CVI) decreased (P ≤ 0.001). During Plateau Phase, HR was lower and RMSSD was higher in 2 m/s compared with 0 m/s condition (P ≤ 0.035), whereas RMSSD and CVI were higher in 2 m/s compared with 4 m/s condition (P ≤ 0.021). We show that HRV responses to prolonged heat exposure in older adults are phase-dependent. Progressive heat storage during Ramp-Up induces HRV responses reflective of vagal withdrawal, regardless of fan use, whereas low-level airflow (2 m/s) during Plateau Phase modestly attenuated reductions in HRV. These findings suggest that the physiological effectiveness of fan use during extreme indoor heat may depend on air flow intensity and temporal progression of heat strain in older adults.NEW & NOTEWORTHY This study demonstrates that cardiac autonomic responses to prolonged heat exposure in older adults are phase-dependent. During the first 4 h of heat exposure (Initial Ramp-Up Phase), regardless of fan use, heart rate variability (HRV) indices reflective of vagal activity declined. Subsequently, during the last 4 h (Plateau Phase), low air flow from an electric fan was associated with modest improvements in HRV when compared with no fan or air flow at higher speeds.

Для цитирования: Carrillo Andres E, O'Connor Fergus K, Cuza-Berry Meghan N, Herry Christophe L, Seely Andrew J E, McCormick James J, Kenny Glen P. Phase-dependent autonomic responses to electric fan use during a prolonged 8-h heat exposure in older adults.. American journal of physiology. Regulatory, integrative and comparative physiology. 2026. DOI: 10.1152/ajpregu.00096.2026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.