Comparing the 1.1 mm cryoprobe versus flexible forceps for lung transplant acute allograft rejection diagnosis.

Balasubramanian Prasanth, Barrios-Ruiz Alanna, Lee-Mateus Alejandra Yu, Valdes-Camacho Sofia, Vaca-Cartagena Bryan F, Funes-Ferrada Rodrigo, Garza-Salas Ana, Khoor Andras, Alvarez Francisco G, Baz Maher, Narula Tathagat, Shah Sadia Z, Bag Remzi, Fernandez-Bussy Sebastian, Abia-Trujillo David

СтатьяНаблюдательное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transbronchial lung biopsy in lung transplant recipients has traditionally been performed via forceps (FBx) but is associated with poor-quality specimens and crush artifacts. The novel 1.1 mm cryoprobe (CBx) with oversheath could obtain a larger sample with better hemostatic control. We hence performed a study comparing FBx and CBx for surveillance biopsy in lung transplant recipients.

METHODS

We conducted a prospective, observational single-center study of adult lung transplant recipients who underwent transbronchial biopsies during surveillance. The samples were obtained with standard transbronchial forceps and 1.1 mm cryoprobe through flexible bronchoscopy for each patient in the same procedure. Outcomes of FBx and CBx were compared and analyzed.

RESULTS

We performed FBx and CBx in 49 patients with a mean age of 62 years, 51 % were male, and 82 % underwent bilateral lung transplant. The CBx yielded a significantly higher area of alveolated tissue compared to FBx (19.3 vs 5.4 mm2, p < 0.001). The diagnostic rate was higher with CBx compared to FBx with respect to acute rejection (100 % vs 96 %), airway inflammation (53 % vs 38 %) and chronic rejection (45 % vs 39 %) though none achieved statistical significance. No major bleeding or pneumothorax were noted in our study.

CONCLUSION

CBx with the 1.1 mm probe could provide a higher rate of detecting lung allograft dysfunction with an excellent safety profile. Similar studies with larger sample sizes are needed to prove statistical significance.

Для цитирования: Balasubramanian Prasanth, Barrios-Ruiz Alanna, Lee-Mateus Alejandra Yu, Valdes-Camacho Sofia, Vaca-Cartagena Bryan F, Funes-Ferrada Rodrigo, Garza-Salas Ana, Khoor Andras, Alvarez Francisco G, Baz Maher, Narula Tathagat, Shah Sadia Z, Bag Remzi, Fernandez-Bussy Sebastian, Abia-Trujillo David. Comparing the 1.1 mm cryoprobe versus flexible forceps for lung transplant acute allograft rejection diagnosis.. Respiratory medicine. 2025. DOI: 10.1016/j.rmed.2025.108061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.