m+Medelevator.RU
← Поиск публикаций
European journal of endocrinology · 2015

18F-FDG PET/CT in the post-operative monitoring of patients with adrenocortical carcinoma.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ardito A, Massaglia C, Pelosi E, Zaggia B, Basile V, Brambilla R, Vigna-Taglianti F, Duregon E, Arena V, Perotti P, Penna D, Terzolo M

Аннотация

CONTEXT: The role of (18)F-labeled 2-fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) in the post-operative monitoring of patients with adrenocortical carcinoma (ACC) is still unclear.

OBJECTIVE: To assess the accuracy of FDG PET/CT to diagnose ACC recurrence in a real world setting.

DESIGN AND METHODS: Retrospective evaluation of data of 57 patients with presumed ACC recurrence at CT scan who underwent FDG PET/CT within a median time of 20 days. We compared the results of either FDG PET/CT or CT with a gold standard confirmation of recurrence (positive histopathology report of removed/biopsied lesions or radiological progression of target lesions at follow-up) to assess their diagnostic performance at different body sites to correctly categorize target lesions. We also assessed whether FDG PET/CT findings may be useful to inform the management strategy.

RESULTS: In 48 patients with confirmed ACC recurrence, we found that FDG PET/CT had lower sensitivity than CT in diagnosing liver and lung recurrences of ACC. FDG PET/CT had higher specificity than CT in categorizing liver lesions. FDG PET/CT had a greater positive likelihood ratio than CT to identify liver and abdominal ACC recurrences. The management strategy was changed based on FDG PET/CT findings in 12 patients (21.1%).

CONCLUSIONS: The greater sensitivity of CT may be partly expected due the specific inclusion criteria of the study; however, the greater specificity of FDG PET/CT was particularly useful in ruling out suspected ACC recurrences found by CT. Thus, use of FDG PET/CT as a second-line test in the post-operative surveillance of ACC patients following CT finding of a potential recurrence may have a significant impact on patient management.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты