m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Radiology : JACR · 2019

Trends in Hospital Performance on the Medicare National Outpatient Imaging Metrics: A 5-Year Longitudinal Cohort Analysis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Narayan Anand K, Rosenkrantz Andrew B, Wang Gary X, Daye Dania, Durand Daniel J

Аннотация

PURPOSE: Medicare established its Hospital Outpatient Quality Reporting Program (HOQRP) to promote and incentivize quality care and appropriate utilization in the hospital outpatient setting. The program includes "imaging efficiency" metrics evaluating appropriate utilization of imaging examinations. Our purpose was to evaluate the longitudinal performance of the nation's hospitals on the HOQPR's imaging efficiency metrics.

METHODS: Data were obtained from CMS Hospital Compare for hospitals participating in the Medicare HOQRP during both initial (January 1, 2011, to December 31, 2011) and follow-up (July 1, 2015, to June 30, 2016) periods. The six reported imaging efficiency metrics were: MRI lumbar spine for low back pain, mammography follow-up rates, abdomen and chest CT double scans (imaging with and without intravenous contrast), cardiac imaging for preoperative risk assessment for low-risk surgery, and simultaneous use of brain and sinus CT. Differences in imaging efficiency metrics were calculated using fixed effects linear regression models.

RESULTS: Baseline and follow-up data were available for 3,960 hospitals. Median changes were MRI lumbar spine for low back pain: +3.6% (range: -27.9% to +31.4%; P < .001); mammography follow-up: -0.3% (range: -69.5% to +62.6%; P = .03); double scan abdomen CT: -1.9% (range: -73.5% to +32.3%; P < .001); double scan chest CT: -0.4% (range: -73.2% to +28.0%; P < .001); preoperative cardiac imaging: -0.7% (range: -10.0% to +9.9%; P < .001); simultaneous brain and sinus CT: -0.9% (range: -11.8% to +7.8%; P < .001).

CONCLUSION: Medicare's nationwide hospital outpatient imaging efficiency reporting initiative was associating with worse performance in lumbar spine MRI utilization and small improvements in double CT scans. Because quality metrics are increasingly imposed on health care providers, health service researchers will need to rigorously evaluate their effectiveness before and during early implementation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты