Quantifying changes in corneal neovascularization using fluorescein and indocyanine green angiography.
Аннотация
PURPOSE: To quantify changes in corneal neovascularization in patients with active keratitis after treatment using color imaging, fluorescein angiography (FA), and indocyanine green angiography (ICGA).
DESIGN
Prospective, interventional case series.
METHODS
Twelve consecutive patients were studied. A comparison of corneal neovascularization parameters was undertaken before and after resolution of the keratitis. A slit-lamp digital camera acquired images of the neovascularization using color imaging, FA, and ICGA. The best-quality images were selected using a grading system, and the neovascular regions of interest were analyzed using automated in-house software. The parameters of analysis were vessel area, diameter, tortuosity, and FA dye leakage.
RESULTS
There was a significant reduction in the area of neovascularization after treatment on color imaging (0.78 mm(2); P < .05), FA (2.33 mm(2); P < .01), and ICGA (2.07 mm(2); P < .01). There was also a significant reduction in mean vessel diameter across the region of interest for each patient, more marked on FA (42.74 to 32.52 μm; P < .01) and ICGA (44.77 to 33.29 μm; P < .01) than on color imaging (29.10 to 25.17 μm; P < .01). A significant change in vessel tortuosity was not observed. There was a significant increase in FA dye leakage time (12.41 seconds; P < .05) after treatment.
CONCLUSIONS
We demonstrate application of an objective method for analyzing changes in corneal neovascularization. The excellent vessel delineation with ICGA even in the presence of stromal scars makes it an ideal agent for measurement of vessel parameters. FA is useful at detecting vessel leakage, and the time to leakage provides a possible measure of vessel staging.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.