m+Medelevator.RU
← Поиск публикаций
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2024

Clinical performance of the Roche Cobas Liat SARS-CoV-2 & influenza A/B assay: A systematic review and meta-analysis.

СтатьяМетаанализСистематический обзорПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chang Eunjin, Jeon Kibum, Lee Nuri, Park Min-Jeong, Song Wonkeun, Kim Hyun Soo, Kim Han-Sung, Kim Jae-Seok, Kim Jimin, Jeong Seri

Аннотация

Respiratory tract infections caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses are persistent and critical. The Cobas Liat SARS-CoV-2 & influenza A/B assay (Multiplex Liat), the FDA-authorized point-of-care reverse transcriptase polymerase chain reaction (RT-PCR) assay, has a turnaround time of 20 min and high accuracy. This study evaluates the pooled performance of this assay to provide practical information. This meta-analysis was registered in PROSPERO (registration number: CRD42023467579). A systematic literature search was conducted within PubMed, Ovid-EMBASE, and the Cochrane Library for articles evaluating the accuracy of the Multiplex Liat assay through September 2023. A random-effects model was used to calculate the pooled diagnostic values with real-time RT-PCR (rRT-PCR) as a reference test. A total of 4,705 samples from eight studies were included in the primary meta-analysis. The overall pooled sensitivity and specificity of Multiplex Liat were 100.0 % (95 % confidence interval [CI] = 96.7 %-100.0 %) and 99.7 % (95 % CI = 98.7 %-99.9 %), respectively. The presence of variants of concern or in-house rRT-PCR assays as reference standards did not significantly affect the pooled diagnostic performance of the Multiplex Liat. When 5,333 samples from nine studies were assessed for sensitivity, the pooled sensitivity was 100.0 % (95 % CI = 85.8 %-100.0 %) without a significant difference. This meta-analysis demonstrates the usefulness of Multiplex Liat for the detection of SARS-CoV-2 based on pooled diagnostic values. These practical findings may facilitate appropriate settings for the diagnosis and management of patients with respiratory tract infections.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты