Sundermann Alexander J, Clancy Cornelius J, Pasculle A William, Liu Guojun, Cheng Shaoji, Cumbie Richard B, Driscoll Eileen, Ayres Ashley, Donahue Lisa, Buck Michael, Streifel Andrew, Muto Carlene A, Nguyen M Hong

Аннотация

BACKGROUND: In an investigation of hospital-acquired mucormycosis cases among transplant recipients, healthcare linens (HCLs) delivered to our center were found to be contaminated with Mucorales. We describe an investigation and remediation of Mucorales contamination at the laundry supplying our center.

METHODS: We performed monthly RODAC cultures of HCLs upon hospital arrival, and conducted site inspections and surveillance cultures at the laundry facility. Remediation was designed and implemented by infection prevention and facility leadership teams.

RESULTS: Prior to remediation, 20% of HCLs were culture-positive for Mucorales upon hospital arrival. Laundry facility layout and processes were consistent with industry standards. Significant step-ups in Mucorales and mold culture-positivity of HCLs were detected at the post-dryer step (0% to 12% [P = .04] and 5% to 29% [P = .01], respectively). Further increases to 17% and 40% culture-positivity, respectively, were noted during pre-transport holding. Site inspection revealed heavy Mucorales-positive lint accumulation in rooftop air intake and exhaust vents that cooled driers; intake and exhaust vents that were facing each other; rooftop and plant-wide lint accumulation, including in the pre-transport clean room; uncovered carts with freshly-laundered HCLs. Following environmental remediation, quality assurance measures and education directed toward these sources, Mucorales culture-positivity of newly-delivered HCLs was reduced to 0.3% (P = .0001); area of lint-contaminated rooftop decreased from 918 m2 to 0 m2 on satellite images.

CONCLUSIONS: Targeted laundry facility interventions guided by site inspections and step-wise culturing significantly reduced Mucorales-contaminated HCLs delivered to our hospital. Collaboration between infection prevention and laundry facility teams was crucial to successful remediation.