Conduction system damage is the most common complication of transcatheter aortic valve replacement (TAVR), which frequently requires placement of a permanent pacemaker. Bundle branch reentry (BBR) is a well-recognized mechanism of ventricular tachycardia (VT) in the setting of abnormal intraventricular conduction. We describe a case of a patient with post-TAVR intraventricular conduction abnormalities who presented with intermittent advanced atrioventricular block and BBR VT and discuss the potential risks, diagnosis, and management of BBR after TAVR.