Performance of a new rapid test for the detection of hepatitis B surface antigen in various patient populations.
Аннотация
BACKGROUND
Rapid diagnostic tests (RDT) have been developed for the detection of hepatitis B surface antigen (HBsAg). They represent a promising alternative to enzyme immunoassays and a powerful tool for large-scale screening and diagnosis of HBV infection, especially in regions without easy access to serological and molecular testing.
OBJECTIVES
The aims of the present study were to evaluate the characteristics and clinical performance of a new CE-marked HBsAg RDT, DRW-HBsAg v2.0 assay (Diagnostics for the Real World™, Ltd., USA), in various patient populations, including those chronically infected with HBV, patients with severe acute hepatitis of unknown origin and pregnant women with unknown HBV serological status at delivery.
RESULTS
The lower limit of detection of the assay, evaluated in 21 clinical samples, ranged from 0.30 ± 0.07 to 0.97 ± 0.26 international units/mL (using Abbott Architect as a reference), depending on the HBV genotype. The assay tested positive in 100% of patients with chronic hepatitis B, 96.3% of HBsAg-positive acute hepatitis patients, and 95.2% of HBsAg-positive pregnant women. Its specificity was 98.8% in HBsAg-negative patients, 98.7% in HBsAg-negative patients with acute hepatitis of unknown origin and 97.8% in HBsAg-negative pregnant women. Amino acid substitutions in the HBsAg major hydrophilic region did not affect HBsAg detection by DRW-HBsAg v2.0.
CONCLUSIONS
The new DRW-HBsAg v2.0 assay is a simple, rapid, easy-to-run and highly sensitive assay that can be used in both high- and low-risk populations for the diagnosis of HBsAg carriage. It appears to be a promising new tool for large-scale screening and diagnosis of HBV infection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.