MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease · 2010

Diagnostic accuracy of the microscopic observation drug susceptibility assay: a pilot study from India.

Michael J S, Daley P, Kalaiselvan S, Latha A, Vijayakumar J, Mathai D, John K R, Pai M

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SETTING

The microscopic observation drug susceptibility (MODS) assay is a rapid, sensitive, low-cost liquid culture technique.

OBJECTIVE

To establish the accuracy of MODS for the detection of active pulmonary tuberculosis (TB), and to document the costs and challenges of setting up this assay in a low-income setting.

DESIGN

Prospective blinded pilot study of 200 adult TB suspects at a tertiary referral hospital in India. Reference standard included culture (Löwenstein-Jensen and automated liquid culture) and clinical diagnosis.

RESULTS

Patients were mostly male (n = 122, 61.1%) and out-patients (n = 184, 92.0%), with a mean age of 40.4 years (standard deviation 16.2). Seventeen (8.5%) were human immunodeficiency virus infected and 47 (23.5%) were reference culture-positive. Compared to reference culture, MODS was 78.9% sensitive (95%CI 62.2-90.0) and 96.7% specific (95%CI 92.0-98.8). Clinical assessment suggested that MODS was false-negative in 3/8 reference culture-positive MODS-negatives and true-positive in 4/6 reference culture-negative MODS-positives. MODS was faster than solid (P < 0.001) and liquid culture (P = 0.088), and cheaper than both.

CONCLUSION

MODS may be a good alternative to automated liquid culture, but there were several challenges in setting up the assay. Prior training and validation, setup costs and inability to rule out cross-contamination need to be taken into account before the test can be established.

Для цитирования: Michael J S, Daley P, Kalaiselvan S, Latha A, Vijayakumar J, Mathai D, John K R, Pai M. Diagnostic accuracy of the microscopic observation drug susceptibility assay: a pilot study from India.. The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease. 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.