MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17562864221118731

Медицинская библиотека · Therapeutic advances in neurological disorders · 2023

Corneal axonal loss as an imaging biomarker of neurodegeneration in multiple sclerosis: a longitudinal study.

Petropoulos Ioannis N, Al-Shibani Fatima, Bitirgen Gulfidan, Ponirakis Georgios, Khan Adnan, Gad Hoda, Mahfoud Ziyad R, Altarawneh Heba, Rehman Muhammad Hassan, John Karen, Al-Merekhi Dhabia, George Pooja, Uca Ali Ulvi, Ozkagnici Ahmet, Ibrahim Faiza, Francis Reny, Canibano Beatriz, Deleu Dirk, El-Sotouhy Ahmed, Vattoth Surjith, Own Ahmed, Shuaib Ashfaq, Akhtar Naveed, Kamran Saadat, Malik Rayaz A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Resourceful endpoints of axonal loss are needed to predict the course of multiple sclerosis (MS). Corneal confocal microscopy (CCM) can detect axonal loss in patients with clinically isolated syndrome and established MS, which relates to neurological disability.

OBJECTIVE

To assess corneal axonal loss over time in relation to retinal atrophy, and neurological and radiological abnormalities in MS.

METHODS

Patients with relapsing-remitting (RRMS) (n = 68) or secondary progressive MS (SPMS) (n = 15) underwent CCM and optical coherence tomography. Corneal nerve fibre density (CNFD-fibres/mm2), corneal nerve branch density (CNBD-branches/mm2), corneal nerve fibre length (CNFL-mm/mm2) and retinal nerve fibre layer (RNFL-μm) thickness were quantified along with neurological and radiological assessments at baseline and after 2 years of follow-up. Age-matched, healthy controls (n = 20) were also assessed.

RESULTS

In patients with RRMS compared with controls at baseline, CNFD (p = 0.004) and RNFL thickness (p < 0.001) were lower, and CNBD (p = 0.003) was higher. In patients with SPMS compared with controls, CNFD (p < 0.001), CNFL (p = 0.04) and RNFL thickness (p < 0.001) were lower. For identifying RRMS, CNBD had the highest area under the receiver operating characteristic (AUROC) curve (0.99); and for SPMS, CNFD had the highest AUROC (0.95). At follow-up, there was a further significant decrease in CNFD (p = 0.04), CNBD (p = 0.001), CNFL (p = 0.008) and RNFL (p = 0.002) in RRMS; in CNFD (p = 0.04) and CNBD (p = 0.002) in SPMS; and in CNBD (p = 0.01) in SPMS compared with RRMS. Follow-up corneal nerve loss was greater in patients with new enhancing lesions and optic neuritis history.

CONCLUSION

Progressive corneal and retinal axonal loss was identified in patients with MS, especially those with more active disease. CCM may serve as an imaging biomarker of axonal loss in MS.

Для цитирования: Petropoulos Ioannis N, Al-Shibani Fatima, Bitirgen Gulfidan, Ponirakis Georgios, Khan Adnan, Gad Hoda, Mahfoud Ziyad R, Altarawneh Heba, Rehman Muhammad Hassan, John Karen, Al-Merekhi Dhabia, George Pooja, Uca Ali Ulvi, Ozkagnici Ahmet, Ibrahim Faiza, Francis Reny, Canibano Beatriz, Deleu Dirk, El-Sotouhy Ahmed, Vattoth Surjith, Own Ahmed, Shuaib Ashfaq, Akhtar Naveed, Kamran Saadat, Malik Rayaz A. Corneal axonal loss as an imaging biomarker of neurodegeneration in multiple sclerosis: a longitudinal study.. Therapeutic advances in neurological disorders. 2023. DOI: 10.1177/17562864221118731.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.