MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-025-07251-w

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2025

Al18F-NOTA-HER2-BCH versus 18F-FDG PET/CT in evaluating newly diagnosed HER2-low breast cancer patients.

Guo Xiaoyi, Liang Xu, Li Ben, Mao Yan, Zhou Nina, Liu Jiayue, Yang Guangjie, Wang Zhenguang, Song Guohong, Yang Zhi

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the diagnostic performance and the whole-body heterogeneity of HER2 expression on Al18F-NOTA-HER2-BCH PET/CT in patients with HER2-low breast cancer.

METHODS

In this prospective study conducted from November 2021 to March 2024, participants with HER2-low breast cancer underwent both Al18F-NOTA-HER2-BCH and 18F-FDG PET/CT. Participants were pathologically confirmed as HER2-low (immunohistochemistry score of 1 + or 2 + without HER2 gene amplification on in situ hybridization). PET/CT images were acquired 3.5 h after injection of 200 MBq of Al18F-NOTA-HER2-BCH. The maximum standardized uptake value (SUVmax) and target-to-background ratios (TBR) were used to quantify tracer uptake.

RESULTS

Fifty-two participants with HER2-low breast cancer (mean age, 53.0 ± 11.0; 52 females) underwent Al18F-NOTA-HER2-BCH and 18F-FDG PET/CT with paired tumor biopsies. No adverse events occurred. The median SUVmax and TBR of 52 HER2-low biopsy lesions on Al18F-NOTA-HER2-BCH PET/CT were lower than that on 18F-FDG PET/CT (6.6 vs. 10.5, P <.001; 8.0 vs. 10.6, P =.009). A total of 269 suspicious lesions were detected, 18F-FDG PET/CT depicted more suspected HER2-low positive lesions in breast (100% vs. 100%), chest wall (100% vs. 100%), lymph node (83.9% vs. 77.7%), bone (100% vs. 93.2%), liver (66.7% vs. 52.4%) and lung (86.7% vs. 75.0%) than Al18F-NOTA-HER2-BCH PET/CT. Additionally, clear interindividual and intraindividual differences on Al18F-NOTA-HER2-BCH tracer uptake was noted between participants, between different metastases in the same participants, even within different organ systems.

CONCLUSION

The visualization of HER2-low breast cancer with Al18F-NOTA-HER2-BCH PET/CT was feasible and safe. The observed intra- and inter-individual heterogeneity in the uptake of Al18F-NOTA-HER2-BCH indicates its potential use as a noninvasive tool for assessing disease heterogeneity and identifying patients who may derive clinical benefit from HER2-targeted therapies.

Для цитирования: Guo Xiaoyi, Liang Xu, Li Ben, Mao Yan, Zhou Nina, Liu Jiayue, Yang Guangjie, Wang Zhenguang, Song Guohong, Yang Zhi. Al18F-NOTA-HER2-BCH versus 18F-FDG PET/CT in evaluating newly diagnosed HER2-low breast cancer patients.. European journal of nuclear medicine and molecular imaging. 2025. DOI: 10.1007/s00259-025-07251-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.