Klinische Monatsblatter fur Augenheilkunde · 1997
[Phototoxic maculopathy after arc welding: value of multifocal ERG].
Клинический случайАннотация на английскомСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Denk P O, Kretschmann U, Gonzalez J, Gelisken F, Knorr M
Аннотация
BACKGROUND: Phototoxic maculopathy most likely results from longer exposure to light from sources such as the sun, welding arcs, tungsten halogen lamp filaments or operation microscopes. The value of the multifocal ERG for the evaluation of functional defects in this rare entity has not been described to date.
CASES: We describe the case of a 38-year-old male patient who presented to his local ophthalmologist with bilateral loss of vision and acute ocular pain after having worked for two hours at an electric welding arc. A foveal lesion was found in both eyes, resulting in a bilateral reduction of visual acuity. Nine months later, the patient underwent examination and further investigations at the university eye clinic in Tübingen. Visual field defects on both sides could be detected with automatic threshold perimetry. Using the multifocal ERG with a central element of 2 degrees diameter, a central defect was detected only for the right eye.
CONCLUSIONS: In rare cases, a photic maculopathy can result from exposure to light during arc welding. It can be masked in the first days by a phototoxic keratitis. Multifocal ERG and automatic perimetry are useful tools for the detection and quantification of the functional defects.
CASES: We describe the case of a 38-year-old male patient who presented to his local ophthalmologist with bilateral loss of vision and acute ocular pain after having worked for two hours at an electric welding arc. A foveal lesion was found in both eyes, resulting in a bilateral reduction of visual acuity. Nine months later, the patient underwent examination and further investigations at the university eye clinic in Tübingen. Visual field defects on both sides could be detected with automatic threshold perimetry. Using the multifocal ERG with a central element of 2 degrees diameter, a central defect was detected only for the right eye.
CONCLUSIONS: In rare cases, a photic maculopathy can result from exposure to light during arc welding. It can be masked in the first days by a phototoxic keratitis. Multifocal ERG and automatic perimetry are useful tools for the detection and quantification of the functional defects.