MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4174/astr.2024.106.5.243

Медицинская библиотека · Annals of surgical treatment and research · 2024

An institutional experience of intraoperative neurophysiological monitoring application in robotic thyroidectomy: a retrospective case-control study.

Lee Joon-Hyop, Kwon Hyungju

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Intraoperative neurophysiological monitoring (IONM) has been introduced in thyroid surgery to prevent injury of the recurrent laryngeal nerve (RLN). However, its effectiveness remains controversial in robotic thyroidectomy (RT). This study aimed to compare the surgical outcome of RT in patients with and without the application of IONM.

METHODS

This retrospective case-control study included 100 patients who underwent total thyroidectomy via robotic bilateral axillo-breast approach in a tertiary center. A study group of 50 patients who had IONM during RT was compared to a control group of 50 patients who underwent RT with nerve visualization alone.

RESULTS

The sex ratio (4:45 vs. 7:43, P = 0.538), mean age (39.3 ± 7.1 years vs. 37.5 ± 10.4 years, P = 0.304), and body mass index (23.1 ± 2.6 kg/m2 vs. 22.2 ± 3.9 kg/m2, P = 0.215) were comparable between the IONM and control groups. Pathologic features including tumor size (0.8 cm vs. 0.9 cm, P = 0.283), extrathyroidal extension (58.0% vs. 24.0%, P = 0.316), lymph node metastasis (30% vs. 34%, P = 0.668), and number of lymph nodes (5.3 vs. 5.3, P = 0.668) showed no differences. There was no permanent RLN palsy, postoperative bleeding, and wound complications. Transient hypoparathyroidism was observed in 12 (24.0%) and 14 (28.0%), permanent hypoparathyroidism in 0 (0%) and 1 (2.0%), and transient RLN palsy was observed in 3 (6.0%) and 3 (6.0%), respectively.

CONCLUSION

We did not demonstrate a clear advantage of IONM in RT. Controversies regarding the effectiveness of IONM is not closed.

Для цитирования: Lee Joon-Hyop, Kwon Hyungju. An institutional experience of intraoperative neurophysiological monitoring application in robotic thyroidectomy: a retrospective case-control study.. Annals of surgical treatment and research. 2024. DOI: 10.4174/astr.2024.106.5.243.