MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12893-024-02360-z

Медицинская библиотека · BMC surgery · 2024

Real-time imaging of ipsilateral parathyroid glands by retrograde injection of methylene blue into the superior thyroid artery: a new intraoperative parathyroid protection method.

Guo Hanjie, Zhang Yuxing, Ren Saiyu, Yang Xiaodong, Tian Lei, Huang Yun, Zhang Chaojun, Zhang Xiliang

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Postoperative hypoparathyroidism caused by parathyroid injury is a problem faced by thyroid surgeons. The current technologies for parathyroid imaging all have some defects.

METHODS

Patients with differentiated thyroid carcinoma (DTC) who underwent unilateral thyroidectomy plus ipsilateral central lymph node dissection were recruited. We dissected the main trunk of the superior thyroid artery entering the thyroid gland and placed the venous indwelling tube into the artery. The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated.

RESULTS

A total of 132 patients enrolled in this single-arm clinical trial, 105 of them completed retrograde catheterization via the superior artery. The sensitivity was 69.23 and 83.33% respectively. The specificity was 72.91 and 64.89%. The accuracy was 72.91 and 64.89%. The PPV was 85.71 and 81.08%. The NPV was 22.58 and 45.45%. There were no patients with allergic reactions to the methylene blue, or methylene blue toxicity.

CONCLUSIONS

Retrograde injection of methylene blue via the superior thyroid artery is an effective and safe method to visualize parathyroid glands. This method can accurately locate the target organ by ultraselecting the blood vessel and injecting the contrast agent while avoiding background contamination and reducing the amount of contrast agent.

TRIAL REGISTRATION: Clinical trial registration numbers and date of registration: ChiCTR2300077263、02/11/2023.

Для цитирования: Guo Hanjie, Zhang Yuxing, Ren Saiyu, Yang Xiaodong, Tian Lei, Huang Yun, Zhang Chaojun, Zhang Xiliang. Real-time imaging of ipsilateral parathyroid glands by retrograde injection of methylene blue into the superior thyroid artery: a new intraoperative parathyroid protection method.. BMC surgery. 2024. DOI: 10.1186/s12893-024-02360-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.