Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

Mahfoud Felix, Tunev Stefan, Ruwart Jennifer, Schulz-Jander Daniel, Cremers Bodo, Linz Dominik, Zeller Thomas, Bhatt Deepak L, Rocha-Singh Krishna, Böhm Michael, Melder Robert J

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA.

METHODS AND

RESULTS

We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries.

CONCLUSIONS

Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent.

Для цитирования: Mahfoud Felix, Tunev Stefan, Ruwart Jennifer, Schulz-Jander Daniel, Cremers Bodo, Linz Dominik, Zeller Thomas, Bhatt Deepak L, Rocha-Singh Krishna, Böhm Michael, Melder Robert J. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.. Circulation. Cardiovascular interventions. 2014. DOI: 10.1161/circinterventions.114.001506.