MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.tube.2012.05.009

Медицинская библиотека · Tuberculosis (Edinburgh, Scotland) · 2012

Rapid detection of Mycobacterium tuberculosis biomarkers in a sandwich immunoassay format using a waveguide-based optical biosensor.

Mukundan Harshini, Kumar Sandeep, Price Dominique N, Ray Sonja M, Lee Ye-Jin, Min Seonyeong, Eum Seokyong, Kubicek-Sutherland Jessica, Resnick Jesse M, Grace W Kevin, Anderson Aaron S, Hwang Soo Hee, Cho Sang Nae, Via Laura E, Barry Clifton, Sakamuri Ramamurthy, Swanson Basil I

СтатьяResearch Support, N.I.H., IntramuralПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Early diagnosis of active tuberculosis (TB) remains an elusive challenge, especially in individuals with disseminated TB and HIV co-infection. Recent studies have shown a promise for the direct detection of pathogen-specific biomarkers such as lipoarabinomannan (LAM) for the diagnosis of TB in HIV-positive individuals. Currently, traditional immunoassay platforms that suffer from poor sensitivity and high non-specific interactions are used for the detection of such biomarkers. In this manuscript, we demonstrate the development of sandwich immunoassays for the direct detection of three TB-specific biomarkers, namely LAM, early secretory antigenic target 6 (ESAT6) and antigen 85 complex (Ag85), using a waveguide-based optical biosensor platform. Combining detection within the evanescent field of a planar optical waveguide with functional surfaces that reduce non-specific interactions allows for the ultra-sensitive and quantitative detection of biomarkers (an order of magnitude enhanced sensitivity, as compared to plate-based ELISA) in complex patient samples (urine, serum) within a short time. We also demonstrate the detection of LAM in urine from a small sample of subjects being treated for TB using this approach with excellent sensitivity and 100% corroboration with disease status. These results suggest that pathogen-specific biomarkers can be applied for the rapid and effective diagnosis of disease. It is likely that detection of a combination of biomarkers offers greater reliability of diagnosis, rather than detection of any single pathogen biomarker. NCT00341601.

Для цитирования: Mukundan Harshini, Kumar Sandeep, Price Dominique N, Ray Sonja M, Lee Ye-Jin, Min Seonyeong, Eum Seokyong, Kubicek-Sutherland Jessica, Resnick Jesse M, Grace W Kevin, Anderson Aaron S, Hwang Soo Hee, Cho Sang Nae, Via Laura E, Barry Clifton, Sakamuri Ramamurthy, Swanson Basil I. Rapid detection of Mycobacterium tuberculosis biomarkers in a sandwich immunoassay format using a waveguide-based optical biosensor.. Tuberculosis (Edinburgh, Scotland). 2012. DOI: 10.1016/j.tube.2012.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.