MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ija.ija_849_22

Медицинская библиотека · Indian journal of anaesthesia · 2023

Comparing two techniques of performing an epidural catheter-assisted epidural blood patch using a 20 ml syringe versus a 5 ml syringe and its effect on clotting time, the strength of clot retraction and haemolysis - A prospective in vitro study (EC-EBP study).

Mariappan Ramamani, Kumar Snehil, Raju Krishnaprabhu, Daniel Dolly, Nair Sukesh Chandran, Subramani Sathya

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Epidural blood patch (EBP) is performed by injecting autologous blood into the epidural space using a Tuohy needle. Certain clinical scenarios mandate an epidural catheter (EC)-assisted EBP. Collecting blood in a 20-ml versus 5-ml syringe appears to influence the quality of the clot. This in vitro study compared the techniques of performing the EC-assisted EBP using 20-ml versus 5-ml syringe on clotting time (CT), clot retraction (CR) and haemolysis.

METHODS

This in vitro study was performed in a haematology laboratory. Five consented adult healthy male volunteers donated blood. In the 5-ml syringe technique, blood was injected through an EC, and as it flowed out of the tip, it was collected at the beginning and the end of 1 min. With the 20-ml technique, blood was collected at the beginning and end of the first, second and third minute. The samples were tested for CT, CR and haemolysis by measuring the plasma-free haemoglobin (PFHb).

RESULTS

Five injections were made using a 5-ml syringe, and another five with a 20-ml syringe. Injection time was shorter in the 5-ml technique (80.80 ± 5.89 vs. 272 ± 28.4 s, P < 0.0001). With the 20-ml technique, CT progressively increased (>15 min), whereas, with the 5-ml syringe, the CT was normal. Both techniques caused mild, insignificant haemolysis (PFHb >0.005 g/dl), without affecting the quality of CR.

CONCLUSION

EC-assisted EBP using a 5-ml syringe technique shortens the injection time and deposits fresh blood quickly without affecting CT and CR.

Для цитирования: Mariappan Ramamani, Kumar Snehil, Raju Krishnaprabhu, Daniel Dolly, Nair Sukesh Chandran, Subramani Sathya. Comparing two techniques of performing an epidural catheter-assisted epidural blood patch using a 20 ml syringe versus a 5 ml syringe and its effect on clotting time, the strength of clot retraction and haemolysis - A prospective in vitro study (EC-EBP study).. Indian journal of anaesthesia. 2023. DOI: 10.4103/ija.ija_849_22.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.