m+Medelevator.RU
← Поиск публикаций
American journal of respiratory and critical care medicine · 2011

Detection of pulmonary emboli with 99mTc-labeled anti-D-dimer (DI-80B3)Fab' fragments (ThromboView).

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Morris Timothy A, Gerometta Michael, Yusen Roger D, White Richard H, Douketis James D, Kaatz Scott, Smart Richard C, Macfarlane David, Ginsberg Jeffrey S

Аннотация

RATIONALE: We report a new method to diagnose acute pulmonary embolism (PE) by single photon emission computerized tomography (SPECT) after administration of (99m)Tc-labeled anti-D-dimer (DI-80B3) monoclonal antibody Fab' fragments. This novel technique provides an additional approach to diagnosing PE in patients for whom other methods are nondiagnostic or contraindicated.

OBJECTIVES: We performed a prospective, multicenter study to investigate the sensitivity and specificity of (99m)Tc-DI-80B3/SPECT in patients with suspected acute PE.

METHODS: Subjects with a moderate to high clinical probability of PE or a positive D-dimer test underwent a PE-protocol contrast-enhanced multidetector thoracic computed tomography (CT) scan as well as (99m)Tc-DI-80B3/SPECT (0.5 mg (99m)Tc-DI-80B3 intravenously followed by a thoracic SPECT 2.5 h later). Separate and independent adjudication committees, blinded to clinical data and other test results, interpreted the (99m)Tc-DI-80B3/SPECT scans (PE detected as foci of abnormally increased (99m)Tc uptake) and the thoracic CT scans using Prospective Investigation of Pulmonary Embolism Diagnosis II criteria.

MEASUREMENTS AND MAIN RESULTS: Of the 52 patients who were enrolled and completed both tests, 42 had both evaluable SPECT scans and thoracic CT scans. Using the criterion standard (thoracic CT scan) there were 21 patients with PE and 21 without. (99m)Tc-DI-80B3/SPECT had a sensitivity of 76.2% (95% confidence interval, 52.8-91.8%) and a specificity of 90.5% (95% confidence interval, 69.8-98.8%). Treatment-related serious adverse events did not occur.

CONCLUSIONS: (99m)Tc-DI-80B3/SPECT was sensitive and specific for acute PE in subjects with moderate to high clinical probability of PE or a positive D-dimer test. (99m)Tc-DI-80B3/SPECT demonstrated an acceptable safety profile and avoids exposure to contrast.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты