The Journal of international medical research · 2013
Comparative evaluation of a novel TaqMan real-time reverse transcription-polymerase chain reaction assay for hepatitis A virus detection.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Qiu Feng, Zheng Huihui, Yi Yao, Jia Zhiyuan, Cao Jingyuan, Bi Shengli
Аннотация
OBJECTIVE: To develop and evaluate a novel system for detecting and quantifying hepatitis A virus (HAV) nucleic acid.
METHODS: Real-time TaqMan® reverse transcription-polymerase chain reaction (PCR) procedures were established, based on amplification of the highly conserved 5'-non-coding region. Synthetic single-stranded RNA transcripts synthesized in vitro were used as the quantification standard. Ten-fold dilutions were prepared from HAV strain stock suspension to determine precision, accuracy, sensitivity and specificity. In addition, serum specimens from patients with acute HAV underwent clinical evaluation.
RESULTS: The novel assay had a detection limit for HAV RNA of 10 TCID50/ml (where TCID50 is median tissue culture infective dose). It was more sensitive and specific than the commercial quantitative PCR kit manufactured by Shanghai Zhijiang Bio-Tech. However, the Artus HAV RT-PCR kit (Qiagen) had the best performance of the three assays and had a detection limit of 5 TCID50/ml. The new HAV real-time PCR detection system was also successfully applied in 90 serum specimens from patients with confirmed acute HAV infection.
CONCLUSION: Considering its high reproducibility, sensitivity, specificity and simplicity, this novel amplification system may be suitable for wide clinical application as a diagnostic tool, and for the surveillance and investigation of infectious diseases in developing countries where HAV is endemic.
METHODS: Real-time TaqMan® reverse transcription-polymerase chain reaction (PCR) procedures were established, based on amplification of the highly conserved 5'-non-coding region. Synthetic single-stranded RNA transcripts synthesized in vitro were used as the quantification standard. Ten-fold dilutions were prepared from HAV strain stock suspension to determine precision, accuracy, sensitivity and specificity. In addition, serum specimens from patients with acute HAV underwent clinical evaluation.
RESULTS: The novel assay had a detection limit for HAV RNA of 10 TCID50/ml (where TCID50 is median tissue culture infective dose). It was more sensitive and specific than the commercial quantitative PCR kit manufactured by Shanghai Zhijiang Bio-Tech. However, the Artus HAV RT-PCR kit (Qiagen) had the best performance of the three assays and had a detection limit of 5 TCID50/ml. The new HAV real-time PCR detection system was also successfully applied in 90 serum specimens from patients with confirmed acute HAV infection.
CONCLUSION: Considering its high reproducibility, sensitivity, specificity and simplicity, this novel amplification system may be suitable for wide clinical application as a diagnostic tool, and for the surveillance and investigation of infectious diseases in developing countries where HAV is endemic.