MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.mp.2024-0191

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025

The Endolymph Signal in Non-contrast Enhanced 3D-real IR Image Differs between the Ears with and without Significant Endolymphatic Hydrops.

Naganawa Shinji, Ito Rintaro, Kawamura Mariko, Taoka Toshiaki, Yoshida Tadao, Sone Michihiko

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate whether significant differences exist in labyrinthine lymph fluid signal intensities on non-contrast-enhanced 3D real inversion recovery (3D-real IR) images between patients with and without significant endolymphatic hydrops (EH), potentially enabling the non-contrast detection of EH.

METHODS

Thirty-nine patients suspected of having EH underwent 3D-real IR MRI before and 4 hours after intravenous administration of a single dose of gadobutrol. Signal intensities of the cerebrospinal fluid (CSF), perilymph, and endolymph were manually measured on pre-contrast images using ROIs. Patients were categorized into 2 groups based on post-contrast imaging: those with significant EH and those without. Normalized signal intensities (nSIs) of the endolymph were calculated and compared between the groups using the Mann-Whitney U test.

RESULTS

The nSIs of the vestibular endolymph on non-contrast 3D-real IR images were significantly lower in the group with significant EH compared to the group without EH (P  < 0.05), suggesting T1 prolongation in the vestibular endolymph of patients with significant EH. However, considerable overlap was observed in the nSIs between the 2 groups, and significant EH did not always result in T1 prolongation. No significant differences were found in the nSIs of the perilymph or CSF between the groups.

CONCLUSION

The study suggests that T1 prolongation occurs in the vestibular endolymph in cases of significant EH. This finding indicates the potential for developing non-contrast MRI methods to detect EH and underscores the importance of understanding the mechanisms behind T1 changes in the endolymph. Further research with larger patient cohorts and inclusion of healthy control subjects is necessary to validate these results and to elucidate the pathophysiology of EH in Ménière's disease.

Для цитирования: Naganawa Shinji, Ito Rintaro, Kawamura Mariko, Taoka Toshiaki, Yoshida Tadao, Sone Michihiko. The Endolymph Signal in Non-contrast Enhanced 3D-real IR Image Differs between the Ears with and without Significant Endolymphatic Hydrops.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2025. DOI: 10.2463/mrms.mp.2024-0191.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.