MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.15217

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2025

Comparing Efficacy and Complications Between Stylet-Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing.

Sripusanapan Adivitch, Wareesawetsuwan Nicha, Deepan Natee, Yinadsawaphan Thanaboon, Qin Dingxin, Rattanawong Pattara, Ng Chee Yuan

СтатьяМетаанализСистематический обзорСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Left bundle branch area pacing (LBBAP) is an emerging technique in conduction system pacing (CSP) that may offer improved outcomes over traditional methods. Typically, lumenless leads are used; however, stylet-driven leads have recently been considered. This study conducts a systematic review and meta-analysis evaluating the efficacy and complications of stylet-driven leads versus lumenless leads.

METHOD: Databases including PubMed, Embase, and Scopus were searched from inception to June 2024 for relevant studies. We included published prospective or retrospective randomized controlled trials and cohort studies using stylet-driven leads or lumenless leads for LBBAP. Data were combined using a random-effects, generic inverse variance method of DerSimonian and Laird.

RESULTS

Sixty-eight studies involving 8996 patients from 2016 to 2023 were included. From eight head-to-head studies, the stylet-driven leads group had a comparable success rate (OR = 1.46, 95% CI: 0.89, 2.39) but showed shorter procedural time (weighted mean difference [WMD] = -16.82 min, 95% CI: -24.42, -9.21). Stylet-driven leads had a higher pacing threshold at implantation (WMD = 0.09 V, 95% CI: 0.00, 0.17) and lower lead impedance (WMD = -86.13 ohms, 95% CI: -129.46, -42.80). QRS duration and R wave amplitude were comparable initially, but at follow-up (1-12 months), stylet-driven leads had a lower R wave amplitude (WMD = -1.92 mV, 95% CI: -3.33, -0.51). Complication rates were higher with stylet-driven leads (OR = 1.80, 95% CI: 1.34, 2.41), particularly lead dislodgement (OR = 3.26, 95% CI: 1.75, 6.07) and helix damage (OR = 11.46, 95% CI: 3.58, 36.63).

CONCLUSION

In this meta-analysis of 8996 patients, stylet-driven leads for LBBAP showed a comparable success rate to lumenless leads but was associated with a higher complication risk.

Для цитирования: Sripusanapan Adivitch, Wareesawetsuwan Nicha, Deepan Natee, Yinadsawaphan Thanaboon, Qin Dingxin, Rattanawong Pattara, Ng Chee Yuan. Comparing Efficacy and Complications Between Stylet-Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing.. Pacing and clinical electrophysiology : PACE. 2025. DOI: 10.1111/pace.15217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.