MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.15209

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2025

Stylet-Driven Lead Vs. Lumenless Lead for Left Bundle Branch Area Pacing: Systematic Literature Review and Meta-Analysis.

Yu Ga-In, Kim Tae-Hoon, Cho Yun-Ho, Bae Jae-Seok, Ahn Jong-Hwa, Jang Jeong Yoon, Kwak Choong Hwan

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Left bundle branch area pacing (LBBAP) offers cardiac synchrony benefits over conventional ventricular pacing. Although many studies on LBBAP have used lumenless pacing leads (LLLs), stylet-driven pacing leads (SDLs) can also be used. In this study, we compared LLLs and SDLs for LBBAP through a systematic review and meta-analysis of the literature.

METHODS

The PubMed, Embase, and Cochrane Library databases were searched for full-text articles on LBBAP from their respective inception dates to April 9, 2024. The studies comparing LLLs and SDLs were extracted, and electrophysiological characteristics and procedural outcomes were analyzed. Of 2201 articles on LBBAP, 7 met the inclusion criteria of comparing LLLs and SDLs as implanted pacing leads.

RESULTS

The overall pooled analysis showed noninferiority in implant success rates for SDLs compared with LLLs for LBBAP (89% vs. 94%, odds ratio: 0.80, 95% confidence interval [CI]: 0.37-1.72, p = 0.566). The paced QRS duration of LBBAP using SDLs was not significantly different from that using LLLs (standardized mean difference: -0.19 ms, 95% CI: -0.50 to 0.12, p = 0.239). There were no differences in the stimulus to the left ventricular activation time and paced QRS duration between the two groups. Follow-up pacing parameters were stable in both groups.

CONCLUSION

LBBAP using SDLs is noninferior to that using LLLs in terms of implantation success. There were no differences in procedural and electrophysiological characteristics between the two groups.

Для цитирования: Yu Ga-In, Kim Tae-Hoon, Cho Yun-Ho, Bae Jae-Seok, Ahn Jong-Hwa, Jang Jeong Yoon, Kwak Choong Hwan. Stylet-Driven Lead Vs. Lumenless Lead for Left Bundle Branch Area Pacing: Systematic Literature Review and Meta-Analysis.. Pacing and clinical electrophysiology : PACE. 2025. DOI: 10.1111/pace.15209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.