m+Medelevator.RU
← Поиск публикаций
Cardiovascular revascularization medicine : including molecular interventions · 2025

Predictors of permanent pacemaker implantation after TAVI with Navitor transcatheter heart valve.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Casenghi Matteo, Corradetti Sara, Rigattieri Stefano, Giovannelli Francesca, Belmonte Marta, Redivo Marco, Terrone Carlo, Barzetti Daniele, Tommasino Antonella, Wyffels Eric, Gallinoro Emanuele, Mistrulli Raffaella, Paolisso Pasquale, Berni Andrea, Vanderheyden Marc, Barbato Emanuele

Аннотация

AIMS: This study aimed to identify predictors of permanent pacemaker implantation (PPI) within 30 days after transcatheter aortic valve implantation (TAVI) using the Navitor™ (Abbott Chicago, IL, USA) transcatheter heart valve (THV).

METHODS AND RESULTS: This retrospective two-center study included 173 patients with severe aortic stenosis undergoing transfemoral TAVI with Navitor™ THV. Patients with prior pacemaker implantation and valve-in-valve procedures were excluded. Mean age was 81.5 ± 5.0 years, and 54 patients (31 %) required PPI; they were more often male (57 % vs. 37 %, p = 0.01), had higher left ventricular ejection fraction (55.3 ± 9.0 vs. 52.4 ± 9.2, p = 0.049), and higher rates of COPD (30 % vs. 16 %, p = 0.017) and pre-existing right bundle branch block (RBBB; 17 % vs. 0.8 %, p < 0.001). Procedural factors associated with PPI included greater annulus-to-THV oversizing (13.6 % ± 3.4 vs. 12.5 % ± 3.1, p = 0.041), implantation depth > 4 mm (75.9 % vs. 52.1 %, p = 0.002), and 29 mm valve size use (46.3 % vs. 26.9 %, p = 0.010). At multivariable analysis, COPD (OR 2.4, p = 0.049), pre-existing RBBB (OR 34.4, p = 0.001), annulus-to-THV oversizing (OR 1.2, p = 0.002), and implantation depth > 4 mm (OR 3.2, p = 0.007) were independent predictors of PPI. ROC analysis (AUC 0.58) identified an optimal cut-off of 15 % annulus-to-THV oversizing for predicting PPI.

CONCLUSIONS: Annulus-to-THV oversizing emerges as a novel independent predictor for PPI after TAVI with Navitor™ THV.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты