MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2024.10.038

Медицинская библиотека · Heart rhythm · 2024

Global R-wave peak time for diagnosis of left bundle branch capture.

Kiełbasa Grzegorz, Moskal Paweł, Bednarek Agnieszka, Jastrzębski Ignacy, Michel Patryk Stanisław, Rajzer Marek, Jastrzębski Marek

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

QRS axis deviation and rS configuration in V6 affect the ability of V6 R-wave peak time (RWPT) criterion to discriminate capture type during left bundle branch area pacing (LBBAP).

OBJECTIVE

We hypothesized that combining RWPTs from lateral leads: I, aVL, V5, and V6 may better reflect left ventricular activation time and that such a global RWPT may be insensitive to changes in QRS configuration.

METHODS

The analysis included 519 electrocardiograms (ECGs) with nonselective left bundle branch pacing (nsLBBP) and 176 ECGs with left ventricular septal pacing (LVSP). Optimal RWPT cutoffs and area under the receiver operating curve (AUC) were determined for each lead and combinations of leads, to find the best RWPT criterion for discriminating nsLBBP from LVSP. Values were reported separately for healthy and diseased left conduction system groups.

RESULTS

The highest AUC of 97.1/89.2% was obtained for the global RWPT, which combined leads I and V6. The AUC for single-lead RWPT, was highest for lead I, followed by V6, V5, and aVL with AUC of 95.1/87.4%, 93.6/87.1%, 93.0/86.5%, and 84.8/74.6%, respectively. The global RWPT criterion was not affected by variations in QRS configuration, as V6 and I RWPTs often showed opposite responses to changes in axis. In contrast, all single-lead RWPT criteria were sensitive to axis deviation and QRS configuration. Diagnostically optimal RWPT cutoffs for global RWPT and lead I RWPT were 162.5/187.5 ms, and 81.5/90.5 ms, respectively.

CONCLUSION

The global RWPT criterion allows a more accurate diagnosis of LBBAP capture type independent of QRS configuration and axis.

Для цитирования: Kiełbasa Grzegorz, Moskal Paweł, Bednarek Agnieszka, Jastrzębski Ignacy, Michel Patryk Stanisław, Rajzer Marek, Jastrzębski Marek. Global R-wave peak time for diagnosis of left bundle branch capture.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.10.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.