MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.201202195

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2013

Acute on-chip HIV detection through label-free electrical sensing of viral nano-lysate.

Shafiee Hadi, Jahangir Muntasir, Inci Fatih, Wang Shuqi, Willenbrecht Remington B M, Giguel Francoise F, Tsibris Athe M N, Kuritzkes Daniel R, Demirci Utkan

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

Development of portable biosensors has broad applications in environmental monitoring, clinical diagnosis, public health, and homeland security. There is an unmet need for pathogen detection at the point-of-care (POC) using a fast, sensitive, inexpensive, and easy-to-use method that does not require complex infrastructure and well-trained technicians. For instance, detection of Human Immunodeficiency Virus (HIV-1) at acute infection stage has been challenging, since current antibody-based POC technologies are not effective due to low concentration of antibodies. In this study, we demonstrated for the first time a label-free electrical sensing method that can detect lysed viruses, i.e. viral nano-lysate, through impedance analysis, offering an alternative technology to the antibody-based methods such as dipsticks and Enzyme-linked Immunosorbent Assay (ELISA). The presented method is a broadly applicable platform technology that can potentially be adapted to detect multiple pathogens utilizing impedance spectroscopy for other infectious diseases including herpes, influenza, hepatitis, pox, malaria, and tuberculosis. The presented method offers a rapid and portable tool that can be used as a detection technology at the POC in resource-constrained settings, as well as hospital and primary care settings.

Для цитирования: Shafiee Hadi, Jahangir Muntasir, Inci Fatih, Wang Shuqi, Willenbrecht Remington B M, Giguel Francoise F, Tsibris Athe M N, Kuritzkes Daniel R, Demirci Utkan. Acute on-chip HIV detection through label-free electrical sensing of viral nano-lysate.. Small (Weinheim an der Bergstrasse, Germany). 2013. DOI: 10.1002/smll.201202195.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.