m+Medelevator.RU
← Поиск публикаций
Frontiers in medicine · 2022

Outcomes of patients with acute respiratory failure on veno-venous extracorporeal membrane oxygenation requiring additional circulatory support by veno-venoarterial extracorporeal membrane oxygenation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Erlebach Rolf, Wild Lennart C, Seeliger Benjamin, Rath Ann-Kathrin, Andermatt Rea, Hofmaenner Daniel A, Schewe Jens-Christian, Ganter Christoph C, Müller Mattia, Putensen Christian, Natanov Ruslan, Kühn Christian, Bauersachs Johann, Welte Tobias, Hoeper Marius M, Wendel-Garcia Pedro D, David Sascha, Bode Christian, Stahl Klaus

Аннотация

OBJECTIVE: Veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) is increasingly used to support patients with severe acute respiratory distress syndrome (ARDS). In case of additional cardio-circulatory failure, some experienced centers upgrade the V-V ECMO with an additional arterial return cannula (termed V-VA ECMO). Here we analyzed short- and long-term outcome together with potential predictors of mortality.

DESIGN: Multicenter, retrospective analysis between January 2008 and September 2021.

SETTING: Three tertiary care ECMO centers in Germany (Hannover, Bonn) and Switzerland (Zurich).

PATIENTS: Seventy-three V-V ECMO patients with ARDS and additional acute cardio-circulatory deterioration required an upgrade to V-VA ECMO were included in this study.

MEASUREMENTS AND MAIN RESULTS: Fifty-three patients required an upgrade from V-V to V-VA and 20 patients were directly triple cannulated. Median (Interquartile Range) age was 49 (28-57) years and SOFA score was 14 (12-17) at V-VA ECMO upgrade. Vasoactive-inotropic score decreased from 53 (12-123) at V-VA ECMO upgrade to 9 (3-37) after 24 h of V-VA ECMO support. Weaning from V-VA and V-V ECMO was successful in 47 (64%) and 40 (55%) patients, respectively. Duration of ECMO support was 12 (6-22) days and ICU length of stay was 32 (16-46) days. Overall ICU mortality was 48% and hospital mortality 51%. Two additional patients died after hospital discharge while the remaining patients survived up to two years (with six patients being lost to follow-up). The vast majority of patients was free from higher degree persistent organ dysfunction at follow-up. A SOFA score > 14 and higher lactate concentrations at the day of V-VA upgrade were independent predictors of mortality in the multivariate regression analysis.

CONCLUSION: In this analysis, the use of V-VA ECMO in patients with ARDS and concomitant cardiocirculatory failure was associated with a hospital survival of about 50%, and most of these patients survived up to 2 years. A SOFA score > 14 and elevated lactate levels at the day of V-VA upgrade predict unfavorable outcome.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты