DOI 10.1111/liv.15531

Медицинская библиотека · Liver international : official journal of the International Association for the Study of the Liver · 2023

Validation of a novel point-of-care test for alanine aminotransferase measurement: A pilot cohort study.

Howell Jessica, Van Huy, Pham Minh D, Sawhney Rohit, Li Fan, Bhat Purnima, Lubel John, Kemp William, Bloom Stephen, Majumdar Avik, McCaughan Geoffrey W, Hall Samuel, Spelman Timothy, Doyle Joseph S, Hellard Margaret, Visvanathan Kumar, Thompson Alexander, Drummer Heidi E, Anderson David

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Alanine aminotransferase (ALT) measurement is essential for evaluation of liver disease. We validated a novel rapid point-of-care (POC) test for ALT1 against laboratory ALT.

METHODS

Stored plasma samples from adults with chronic liver disease (Test cohort n = 240; Validation cohort n = 491) were analysed using the BioPoint® antigen immunoassay POC ALT1 lateral flow test, which provides quantitative ALT results (Axxin handheld reader) or semi-quantitative results (visual read, cut off 40 IU/ml). The accuracy of POC ALT1 to detect ALT > 40 IU/L was determined by ROC analysis. In patients with chronic hepatitis B, treatment eligibility (EASL criteria) was determined using POC ALT1 and compared to laboratory ALT.

RESULTS

POC ALT1 test had good accuracy for laboratory ALT > 40 IU/L: AUROC 0.93 (95% CI: 0.89-0.96) in the Test cohort and AUROC 0.92 (95% CI: 0.88-0.95) in the Validation cohort. POC ALT1 cut off of 0.8 for ALT > 40 IU/L maximised sensitivity (97%) and specificity (71%) in the Test cohort (42% laboratory ALT > 40 IU/L) and yielded PPV 84% and NPV 91% in the Validation cohort (19% laboratory ALT > 40 IU/L). Semi-quantitative POC ALT1 had good accuracy for laboratory ALT in the Validation cohort (AUROC 0.85, 95% CI: 0.81-0.99; sensitivity 77% and specificity 93%). Combined with HBV DNA and transient elastography, both quantitative and semi-quantitative POC ALT1 tests had good accuracy for excluding hepatitis B treatment needs (sensitivity 96%, specificity 78% and NPV 99%).

CONCLUSION

The POC ALT1 test had good accuracy for elevated ALT levels and for determining treatment eligibility among people with chronic hepatitis B.

Для цитирования: Howell Jessica, Van Huy, Pham Minh D, Sawhney Rohit, Li Fan, Bhat Purnima, Lubel John, Kemp William, Bloom Stephen, Majumdar Avik, McCaughan Geoffrey W, Hall Samuel, Spelman Timothy, Doyle Joseph S, Hellard Margaret, Visvanathan Kumar, Thompson Alexander, Drummer Heidi E, Anderson David. Validation of a novel point-of-care test for alanine aminotransferase measurement: A pilot cohort study.. Liver international : official journal of the International Association for the Study of the Liver. 2023. DOI: 10.1111/liv.15531.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.