MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2006.08.030

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2006

N-acetylgalactosamine-6-sulfatase protein detection in MPS IVA patient and unaffected control samples.

Parkinson-Lawrence Emma J, Muller Viv J, Hopwood John J, Brooks Doug A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Mucopolysaccharidosis type IVA (MPS IVA; Morquio syndrome) is a lysosomal storage disorder caused by a deficiency in the activity of the lysosomal hydrolase N-acetylgalactosamine-6-sulfatase (GALNS). MPS IVA patients can present with severe myelopathy, hearing loss, heart valve involvement, short trunk/dwarfism and corneal clouding. Early diagnosis of MPS IVA will allow potential treatments to be implemented before the onset of irreversible pathology.

METHODS

We have developed a sensitive immune-quantification assay for the accurate detection of GALNS protein in skin fibroblasts, blood and plasma from unaffected control and MPS IVA patients.

RESULTS

MPS IVA patient fibroblast extracts (n=11) had non-detectable (ND)-10 ng/mg of 6-sulfatase protein compared to 3-82 ng/mg for normal controls (n=19). Dried blood-spots from MPS IVA patients (n=4) contained ND-1.3 ng/L of 6-sulfatase protein compared to 18-145 ng/L for normal controls (n=49). Plasma from MPS IVA patients (n=7) contained ND 6-sulfatase protein compared to 1-9 ng/L for normal controls (n=49).

CONCLUSIONS

The immune assay described here had the capacity to accurately measure the amount of GALNS protein in various biological samples, providing the basis of an assay that could be further developed to enable newborn and high-risk population screening for MPS IVA patients.

Для цитирования: Parkinson-Lawrence Emma J, Muller Viv J, Hopwood John J, Brooks Doug A. N-acetylgalactosamine-6-sulfatase protein detection in MPS IVA patient and unaffected control samples.. Clinica chimica acta; international journal of clinical chemistry. 2006. DOI: 10.1016/j.cca.2006.08.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.