Optical coherence tomography confirms shunt malfunction and recurrence of raised intracranial pressure in optic atrophy.

Qureshi Ahoane, Virdee Jasvir, Tsermoulas Georgios, Sinclair Alex J, Mollan Susan P

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Investigating potential cerebrospinal fluid (CSF) shunt malfunction can be a challenge. Optical coherence tomography (OCT), a non-invasive imaging technique, is used to monitor changes at the optic nerve head in papilloedema. Conventional teaching suggests that in the presence of optic atrophy the optic nerve head may not re-swell in response to a relapse in raised intracranial pressure (ICP).

METHODS

A retrospective case series of three patients who had prior CSF diversion surgery for idiopathic intracranial cranial hypertension (IIH) is presented demonstrating the benefit of non-invasive OCT imaging confirming raised ICP.

RESULTS

Recurrence of raised ICP, due to malfunctioning CSF shunt, was diagnosed in three patients requiring further surgical intervention. All re-presented acutely with headache and visual disturbances. All had a prior diagnosis of optic atrophy. In all patients, OCT peripapillary retinal nerve fibre layer qualitative image analysis and quantified progression analysis permitted easy detection of the recurrence of papilloedema.

CONCLUSION

OCT imaging supports clinical decision making in shunt malfunction, even in the presence of established optic atrophy secondary to IIH.

Для цитирования: Qureshi Ahoane, Virdee Jasvir, Tsermoulas Georgios, Sinclair Alex J, Mollan Susan P. Optical coherence tomography confirms shunt malfunction and recurrence of raised intracranial pressure in optic atrophy.. British journal of neurosurgery. 2020. DOI: 10.1080/02688697.2020.1844146.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.