MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000515442

Медицинская библиотека · Respiration; international review of thoracic diseases · 2021

Assessment of Extensive Airway Obstruction Using Point-by-Point Lateral Pressure Measurements during Bronchoscopy.

Nishine Hiroki, Hiramoto Takehiko, Handa Hiroshi, Inoue Takeo, Wakahara Keiko, Saka Hideo, Miyazawa Teruomi, Mineshita Masamichi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The positioning of the stent at the flow-limiting segment is crucial for patients with extensive airway obstruction to relieve dyspnea. However, CT and flow-volume curves cannot detect the area of maximal obstruction.

OBJECTIVES

The aim of this study is to physiologically evaluate extensive airway obstruction during interventional bronchoscopy.

METHODS

We prospectively measured point-by-point lateral airway pressure (Plat) at multiple points from the lower lobe bronchus to the upper trachea using a double-lumen catheter in 5 patients. The site of maximal obstruction was evaluated continuously to measure point-by-point Plat at multiple points when the airway catheter was withdrawn from the lower lobe bronchus to the upper trachea.

RESULTS

Remarkable pressure differences occurred at the site of maximal obstruction assessed by point-by-point Plat measurements. After initial stenting in 1 case, migration of the maximal obstruction to a nonstented segment of the weakened airway was seen with extensive stenosis from the trachea to the bronchi. In the second case, in addition to radiological analysis, point-by-point Plat measurements could identify the location of the maximal obstruction which contributed to dyspnea.

CONCLUSIONS

Point-by-point Plat measurement could be used to detect the site of maximal obstruction physiologically. Furthermore, Plat measurement could assess the need for additional procedures in real time in patients with extensive airway obstruction.

Для цитирования: Nishine Hiroki, Hiramoto Takehiko, Handa Hiroshi, Inoue Takeo, Wakahara Keiko, Saka Hideo, Miyazawa Teruomi, Mineshita Masamichi. Assessment of Extensive Airway Obstruction Using Point-by-Point Lateral Pressure Measurements during Bronchoscopy.. Respiration; international review of thoracic diseases. 2021. DOI: 10.1159/000515442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.