MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2012.07.027

Медицинская библиотека · Journal of virological methods · 2012

Minor groove binder modification of widely used TaqMan probe for hepatitis E virus reduces risk of false negative real-time PCR results.

Garson Jeremy A, Ferns Ruth B, Grant Paul R, Ijaz Samreen, Nastouli Eleni, Szypulska Renata, Tedder Richard S

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Hepatitis E virus (HEV) is a major cause of acute viral hepatitis in many parts of the developing world. It is responsible for both sporadic infections and large scale epidemics and may be associated with significant mortality during pregnancy. Over the past two decades many serological and nucleic acid based diagnostic tests for HEV have been developed, including several reverse transcription real-time polymerase chain reaction assays (RT-qPCR). One of the most widely used of these RT-qPCRs is that developed by Jothikumar and colleagues (Journal of Virological Methods 2006, 131, 65-71). Whilst reviewing this assay we calculated the predicted melting temperature of its TaqMan probe and consequently synthesised a minor groove binder (MGB) version in order to increase its hybridisation stability. In this report the performance of the original unmodified probe is compared with that of the MGB-modified version. We demonstrate that the MGB-modified probe detected HEV RNA in plasma samples from six patients with serologically confirmed hepatitis E in whom the unmodified probe had failed to detect HEV RNA. Sequence analysis of the ORF3 segment targeted by the RT-qPCR was possible in 4 of the 6 patients and revealed an identical C→T single nucleotide mutation in the probe binding region in each case.

Для цитирования: Garson Jeremy A, Ferns Ruth B, Grant Paul R, Ijaz Samreen, Nastouli Eleni, Szypulska Renata, Tedder Richard S. Minor groove binder modification of widely used TaqMan probe for hepatitis E virus reduces risk of false negative real-time PCR results.. Journal of virological methods. 2012. DOI: 10.1016/j.jviromet.2012.07.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.