MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jscai.2023.100629

Медицинская библиотека · Journal of the Society for Cardiovascular Angiography & Interventions · 2023

The Supreme Biodegradable Polymer DES in Acute and Chronic Coronary Syndromes: A PIONEER III Substudy.

Hussain Yasin, Saito Shigeru, Curtis Michael, Kereiakes Dean J, Baumbach Andreas, Zidar James P, McLaurin Brent, Dib Nabil, Smits Pieter C, Jiménez Díaz Victor Alfonso, Cequier Ángel, Hofma Sjoerd H, Pietras Cody, Dressler Ovidiu, Issever M Ozgu, Windecker Stephan, Leon Martin B, Lansky Alexandra J, PIONEER III Trial Investigators

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The PIONEER III trial demonstrated noninferiority of 12-month target lesion failure (TLF) with the Supreme DES (Sinomed), a thin-strut cobalt-chromium, biodegradable polymer, sirolimus-eluting stent, compared with a durable polymer, everolimus-eluting (XIENCE/PROMUS) stent (DP-EES). The relative safety and effectiveness of the Supreme DES in patients with acute coronary syndromes (ACS) and those with chronic coronary syndromes (CCS) is not known.

METHODS

PIONEER III was a prospective, multicenter, international, 2:1 randomized trial stratified by clinical presentation. The primary end point was TLF at 12 months (a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization).

RESULTS

A total of 1628 patients were enrolled, including 41% of patients with ACS (unstable angina and non-ST-elevation myocardial infarction) randomized to Supreme DES (n = 441) versus DP-EES (n = 232) and 59% of patients with CCS randomized to Supreme DES (n = 645) versus DP-EES (n = 310). Patients with ACS were younger, fewer presented with less diabetes, hypertension, and previous revascularization, but more were current smokers. The primary end point of TLF (6.4% vs 4.4%; P = .1), major adverse cardiac events (8.5% vs 6.5%; P = .16), and stent thrombosis (0.4% vs 0.9%; P = .25) at 12 months were similar in the ACS and CCS groups. There was no difference in TLF at 12 months between Supreme DES and DP-EES among patients with ACS (6.6% vs 6.0%; P = .89) and those with CCS (4.5% vs 4.3%; P = .83); interaction P = .51 for TLF by clinical presentation.

CONCLUSIONS

Compared with the DP-EES, the Supreme DES seemed safe and effective with a similar TLF at 12 months in both patients with ACS and those with CCS.

Для цитирования: Hussain Yasin, Saito Shigeru, Curtis Michael, Kereiakes Dean J, Baumbach Andreas, Zidar James P, McLaurin Brent, Dib Nabil, Smits Pieter C, Jiménez Díaz Victor Alfonso, Cequier Ángel, Hofma Sjoerd H, Pietras Cody, Dressler Ovidiu, Issever M Ozgu, Windecker Stephan, Leon Martin B, Lansky Alexandra J, PIONEER III Trial Investigators. The Supreme Biodegradable Polymer DES in Acute and Chronic Coronary Syndromes: A PIONEER III Substudy.. Journal of the Society for Cardiovascular Angiography & Interventions. 2023. DOI: 10.1016/j.jscai.2023.100629.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.