m+Medelevator.RU
← Поиск публикаций
Infection control and hospital epidemiology · 2022

Clean clothes or dirty clothes? Outbreak investigation of carbapenem-resistant Acinetobacter baumannii related to laundry contamination through multilocus sequence typing (MLST).

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Alfred Lok Hang, Leung Eddie Chi Ming, Wong Ben Wai Hong, Wong Leo Chun Hei, Wong Yoyo Lok Yiu, Hung Rosana Ka Yin, Ho Sindy Sin Yee, Chow Viola Chi Ying

Аннотация

OBJECTIVE: To investigate the source in an outbreak of carbapenem-resistant Acinetobacter baumannii (CRA) in a general hospital due to contamination of a laundry evaporative cooler and the laundry environment using multilocus sequence typing (MLST).

METHODS: For CRA culture, clinical samples were collected from infected patients and close contacts, and environmental sampling was performed in patient surroundings and laundry facilities. MLST was used for the molecular typing of representative CRA isolates. Bacterial isolates with identical sequence types were considered epidemiologically linked and attributable to the same source. OXA genes in Acinetobacter baumannii were detected using polymerase chain reaction (PCR).

RESULTS: In total, 58 patients were affected in this outbreak. The mean patient age was 75.3, and 50% were female. The most common diagnoses at admission were skin and soft-tissue infection (n = 12, 20.7%) and pneumonia (n = 12, 20.7%). OXA-23 was positive in 64.7% of isolates. A CRA isolate from the evaporative cooler in the laundry was identical to that of 11 patients across 3 wards, belonging to ST345. Isolates from 3 laundry linen racks were identical to those of 7 patients from 3 wards, classified as ST1145. Isolates found on another linen rack and a pajama shelf were identical to isolates from 3 other patients from 2 wards, belonging to ST2207. There was no significant difference between sequence type distributions of clinical and environmental isolates (P = .12), indicating high likelihood of CRA originating from the same source.

CONCLUSIONS: MLST confirmed that contamination of the laundry evaporative cooler and surrounding environment caused a polyclonal CRA hospital outbreak. Hospital laundry is an important area for infection control and outbreak investigations of CRA.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты