MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e318183a379

Медицинская библиотека · Cornea · 2009

Histologic evaluation of human posterior lamellar discs for femtosecond laser Descemet's stripping endothelial keratoplasty.

Cheng Yanny Y Y, Kang Shin J, Grossniklaus Hans E, Pels Elisabeth, Duimel Hans J Q, Frederik Peter M, Hendrikse Fred, Nuijts Rudy M M A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the histologic changes in corneal structure after femtosecond laser preparation of posterior lamellar discs, more specifically, the smoothness of the stromal bed and the accuracy of the predicted depth of the horizontal lamellar cut.

MATERIALS AND

METHODS

Nineteen human donor eyes unsuitable for transplantation were used. Femtosecond laser was used to prepare a horizontal lamellar cut in donor corneas at a depth of 400 microm. Transmission electron microscopy images were used to evaluate the changes in the corneal structure and to measure the damage zone. Scanning electron microscopy images were used to determine the relative depth of the horizontal lamellar cut, and the stromal bed was examined to determine the smoothness of the surface.

RESULTS

Transmission electron microscopy images showed a mean damage zone of 6.8 +/- 3.1 microm, which consisted of irregularly oriented collagen fibrils and electron-dense granular material. The collagen lamellae, both anteriorly and posteriorly of the damaged zone, showed a regular parallel configuration. The relative depth of the horizontal lamellar cut as percentage of the total corneal thickness in the center and periphery was 70.4% +/- 4.5% and 55.6% +/- 5.9%. Scanning electron microscopy images of the stromal bed showed a relatively smooth surface.

CONCLUSION

The femtosecond laser is effective to prepare a deep horizontal lamellar cut in a standardized method. The stromal bed is smooth and without extensive adjacent tissue damage. The is thinner in the center and thicker at the edges, which may produce a mild hyperopic shift after femtosecond laser-assisted Descemet's stripping endothelial keratoplasty.

Для цитирования: Cheng Yanny Y Y, Kang Shin J, Grossniklaus Hans E, Pels Elisabeth, Duimel Hans J Q, Frederik Peter M, Hendrikse Fred, Nuijts Rudy M M A. Histologic evaluation of human posterior lamellar discs for femtosecond laser Descemet's stripping endothelial keratoplasty.. Cornea. 2009. DOI: 10.1097/ico.0b013e318183a379.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.