MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0300060518813742

Медицинская библиотека · The Journal of international medical research · 2018

99mTcO4-/99mTc-MIBI dual-tracer scintigraphy for preoperative localization of parathyroid adenomas.

Huang Zhongke, Lou Cen

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the accuracy of dual-tracer scintigraphy for locating parathyroid adenomas in patients with primary hyperparathyroidism (PHPT).

METHODS

We reviewed 268 patients with PHPT. All patients underwent technetium-99m pertechnetate (99mTcO4-) scintigraphy and technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) dual-tracer scintigraphy of the thyroid and parathyroid glands, respectively. 99mTcO4- planar scintigraphy was carried out initially followed by dual-phase 99mTc-MIBI single-photon emission computed tomography (SPECT)/CT the next day. The findings were combined and interpreted. Individual 99mTc-MIBI and dual-tracer scintigraphy were both analyzed. The sensitivity, specificity, and accuracy were determined in relation to surgical findings. The average interval between scan and surgery was 13 days.

RESULTS

The positive and negative predictive values of 99mTc-MIBI SPECT/CT were 92.0% and 71.3%, respectively, and the sensitivity, specificity, and accuracy were 88.3%, 79.2%, and 85.8%, respectively. The positive and negative predictive values of dual-tracer scintigraphy were 96.3% and 82.3%, respectively, and the sensitivity, specificity, and accuracy were 92.9%, 90.3%, and 92.2%, respectively. Youden's index for dual-tracer scintigraphy and 99mTc-MIBI SPECT/CT were 0.83 and 0.63, respectively.

CONCLUSIONS

These finding suggest that 99mTcO4- and 99mTc-MIBI dual-tracer scintigraphy is more accurate than other scintigraphy methods for detecting parathyroid adenoma, and may thus be the most suitable imaging technique in patients with PHPT.

Для цитирования: Huang Zhongke, Lou Cen. 99mTcO4-/99mTc-MIBI dual-tracer scintigraphy for preoperative localization of parathyroid adenomas.. The Journal of international medical research. 2018. DOI: 10.1177/0300060518813742.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.