m+Medelevator.RU
← Поиск публикаций
The international journal of cardiovascular imaging · 2024

Mitral regurgitation assessment by cardiovascular magnetic resonance imaging during continuous in-scanner exercise: a feasibility study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gorecka Miroslawa, Craven Thomas P, Jex Nick, Chew Pei G, Dobson Laura E, Brown Louise A E, Higgins David M, Thirunavukarasu Sharmaine, Sharrack Noor, Javed Wasim, Kotha Sindhoora, Giannoudi Marilena, Procter Henry, Parent Martine, Schlosshan Dominik, Swoboda Peter P, Plein Sven, Levelt Eylem, Greenwood John P

Аннотация

PURPOSE: Exercise imaging using current modalities can be challenging. This was patient focused study to establish the feasibility and reproducibility of exercise-cardiovascular magnetic resonance imaging (EX-CMR) acquired during continuous in-scanner exercise in asymptomatic patients with primary mitral regurgitation (MR).

METHODS: This was a prospective, feasibility study. Biventricular volumes/function, aortic flow volume, MR volume (MR-Rvol) and regurgitant fraction (MR-RF) were assessed at rest and during low- (Low-EX) and moderate-intensity exercise (Mod-EX) in asymptomatic patients with primary MR.

RESULTS: Twenty-five patients completed EX-CMR without complications. Whilst there were no significant changes in the left ventricular (LV) volumes, there was a significant increase in the LVEF (rest 63 ± 5% vs. Mod-EX 68 ± 6%;p = 0.01). There was a significant reduction in the right ventricular (RV) end-systolic volume (rest 68 ml(60-75) vs. Mod-EX 46 ml(39-59);p < 0.001) and a significant increase in the RV ejection fraction (rest 55 ± 5% vs. Mod-EX 65 ± 8%;p < 0.001). Whilst overall, there were no significant group changes in the MR-Rvol and MR-RF, individual responses were variable, with MR-Rvol increasing by ≥ 15 ml in 4(16%) patients and decreasing by ≥ 15 ml in 9(36%) of patients. The intra- and inter-observer reproducibility of LV volumes and aortic flow measurements were excellent, including at Mod-EX.

CONCLUSION: EX-CMR is feasible and reproducible in patients with primary MR. During exercise, there is an increase in the LV and RV ejection fraction, reduction in the RV end-systolic volume and a variable response of MR-Rvol and MR-RF. Understanding the individual variability in MR-Rvol and MR-RF during physiological exercise may be clinically important.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты