MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jiph.2019.06.027

Медицинская библиотека · Journal of infection and public health · 2019

Information feedback of 18F-FDG PET/CT computer imaging combined with tumor markers on recurrence and metastasis of non-small cell lung cancer.

Mu Yindong, Gui Jinqiu, Lang Zhifang, Ren Chunhui, Yan Lei, Liu Haifeng, Liang Jun, Feng Hua

СтатьяПеревод пока не подготовлен

Аннотация

To investigate the diagnostic value or information feedback of tumor markers combined with 18F-FDG PET/CT computer imaging on recurrence and metastasis of non-small cell lung cancer (NSCLC).

METHODS

From January 2013 to December 2017, 95 NSCLC patients undergoing systemic 18F-FDG PET/CT computer imaging examination at the PET/CT computer imaging center of Mudanjiang Medical University had been enrolled. Typically, the interval between the completion of treatment and PET/CT computer imaging examination should be at least three months. Besides, all patients had undergone serum CEA monitoring before and after 18F-FDG PET/CT computer imaging, and 70 of them had received CYFRA21-1 test at the same time. Tumor markers were examined with PET/CT at intervals of less than one week, and all the feedback results were compared with clinical follow-up results or final pathology. Additionally, all the enrolled patients were followed up for 6-12 months.

RESULTS

The sensitivity, accuracy, specificity, positive predictive value and negative predictive value of 18F-FDGPET/CT information feedback in evaluating recurrence or metastasis after NSCLC treatment were superior to those of common tumor markers, and the differences were statistically significant (P<0.05). Those of 18F-FDG PET/CT computer imaging combined with tumor marker examination for the recurrence and/or metastasis after NSCLC treatment were remarkably higher than those of either individual examination, and the accuracy difference of information feedback had significant statistical significance (P<0.05). Clearly, the diagnosis using tumor markers was correlated with that by 18F-FDG PET/CT imaging, and the correlation coefficient was r=0.63. Moreover, serum CEA was grouped at different levels, and the positive rate and accuracy of 18F-FDG PET/CT computer imaging diagnosis were increased with the increase in CEA level. 8 patients had received 18F-FDG PET/CT dual-phase examination, among them, 4 were diagnosed with recurrence or metastasis after MSCLC treatment, and all of them had been detected.

Для цитирования: Mu Yindong, Gui Jinqiu, Lang Zhifang, Ren Chunhui, Yan Lei, Liu Haifeng, Liang Jun, Feng Hua. Information feedback of 18F-FDG PET/CT computer imaging combined with tumor markers on recurrence and metastasis of non-small cell lung cancer.. Journal of infection and public health. 2019. DOI: 10.1016/j.jiph.2019.06.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.