MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/sj.leu.2404241

Медицинская библиотека · Leukemia · 2006

A new automated flow cytometry data analysis approach for the diagnostic screening of neoplastic B-cell disorders in peripheral blood samples with absolute lymphocytosis.

Costa E S, Arroyo M E, Pedreira C E, García-Marcos M A, Tabernero M D, Almeida J, Orfao A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Currently, multiparameter flow cytometry immunophenotyping is the selected method for the differential diagnostic screening between reactive lymphocytosis and neoplastic B-cell chronic lymphoproliferative disorders (B-CLPD). Despite this, current multiparameter flow cytometry data analysis approaches still remain subjective due to the need of experienced personnel for both data analysis and interpretation of the results. In this study, we describe and validate a new automated method based on vector quantization algorithms to analyze multiparameter flow cytometry immunophenotyping data in a series of 307 peripheral blood (PB) samples. Our results show that the automated method of analysis proposed compares well with currently used manual approach and significantly improves semiautomated approaches and, that by using it, a highly efficient discrimination with 100% specificity and 100% sensitivity can be made between normal/reactive PB samples and cases with B-CLPD based on the total B-cell number and/or the sIgkappa+/sIglambda+ B-cell ratio. In addition, the method proved to be able to detect the presence of pathologic neoplastic B-cells even when these are present at low frequencies (<5% of all lymphocytes in the sample) and in poor-quality samples enriched in 'noise' events.

Для цитирования: Costa E S, Arroyo M E, Pedreira C E, García-Marcos M A, Tabernero M D, Almeida J, Orfao A. A new automated flow cytometry data analysis approach for the diagnostic screening of neoplastic B-cell disorders in peripheral blood samples with absolute lymphocytosis.. Leukemia. 2006. DOI: 10.1038/sj.leu.2404241.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.