Arrhythmia insensitive rapid cardiac T1 mapping: comparison to modified look locker inversion recovery T1 mapping in mitral valve prolapse patients.

Cheung Ernest, Han Hui-Chen, Hornsey Emma, Churilov Leonid, Hong Kyung Pyo, Smith Julie, Kim Daniel, Farouque Omar, Teh Andrew, Lim Han, Lim Ruth P

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

We compare a saturation recovery arrhythmia insensitive rapid (AIR) T1 mapping technique which is less sensitive to heart rate and requires shorter breath-holds to modified Look-Locker inversion recovery (MOLLI) T1 mapping in patients with mitral valve prolapse. 55 patients underwent AIR and MOLLI at 1.5 T. AIR and MOLLI-derived blood and myocardial T1 values and extracellular volume (ECV) were measured by two independent readers. T1 values and ECV from both techniques and inter-reader agreement were compared with Lin's concordance correlation coefficient (LCC) and reduced major axis regression. T1 values were consistently overestimated for AIR compared to MOLLI and vice versa for ECV. In the mitral valve prolapse population, mean native and post contrast myocardial T1 value for MOLLI were 1000 ± 40 ms and 411.9 ± 44.2 ms respectively and 1090.6 ± 58.7 ms and 488.2 ± 45.7 ms for AIR. Mean native and post contrast blood T1 values for MOLLI were 1566.6 ± 72.3 ms and 276.6 ± 34.1 ms respectively versus 1657.2 ± 180.9 ms and 294.9 ± 35.6 ms for AIR. AIR underestimated ECV relative to MOLLI (23.5 ± 0.4% vs 27.7 ± 0.4%). We found excellent inter-reader agreement (LCC all > 0.94, p < 0.0001) for both AIR and MOLLI techniques as well as intra-reader reliability (LCC all > 0.97, p < 0.0001). AIR can be performed in patients with mitral valve prolapse with excellent inter and intra-reader agreement, with higher T1 values compared to MOLLI, in line with other saturation recovery techniques. A consistent T1 mapping technique should be used when performing serial imaging.

Для цитирования: Cheung Ernest, Han Hui-Chen, Hornsey Emma, Churilov Leonid, Hong Kyung Pyo, Smith Julie, Kim Daniel, Farouque Omar, Teh Andrew, Lim Han, Lim Ruth P. Arrhythmia insensitive rapid cardiac T1 mapping: comparison to modified look locker inversion recovery T1 mapping in mitral valve prolapse patients.. The international journal of cardiovascular imaging. 2020. DOI: 10.1007/s10554-020-01910-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.