Application of trans-thoracic echocardiography and coronary CT angiography to diagnose mitral valve prolapse.

Li Jingbo, Zhang Yun, Zhang Liulong, Lv Deyong, Song Hui, Zhang Haifeng, Zhou Guangyan, Li Hong

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

At present, multi-detector cardiac CT has been widely applied in the detection of heart valve morphology and function. This study aims to compare the coronary CT angiography and trans-thoracic echocardiography for patients with mitral valve prolapse.

METHODS

CT angiography and trans-thoracic echocardiography were adopted to detect the movement range and thickness of valvula bicuspidalis. The ultrasonic parameters of CT angiography were considered as standard reference value.

RESULTS

Receiver operating characteristic (ROC) curve showed that the area of mitral valve motion amplitude under ROC curve was 95% detected by CT angiography with statistical significance (P < 0.001). Based on the intercept point on the ROC curve, the sensitivity and accuracy of mitral valve amplitude detected by CT angiography was 69.2 and 95.6%, the false positive and false negative rate was 5.2 and 32.4%, the predicted value of positive and negative was 92.9 and 76.9% and the consistency rate of motion range and leaf thickness detected by CT angiography was 83.3 and 47.5%. Trans-thoracic echocardiography showed that the thickness and motion range of mitral leaflet was (1.95 ± 0.22) mm and (1.5 ± 2.28) mm. The thickness and motion range of mitral leaflet that detected by CT was (2.00 ± 0.54) mm and (3.76 ± 2.1) mm.

CONCLUSION

The accuracy and reliability of CT angiography for patients with mitral valve prolapse are higher than those of trans-thoracic echocardiography.

Для цитирования: Li Jingbo, Zhang Yun, Zhang Liulong, Lv Deyong, Song Hui, Zhang Haifeng, Zhou Guangyan, Li Hong. Application of trans-thoracic echocardiography and coronary CT angiography to diagnose mitral valve prolapse.. Journal of cardiothoracic surgery. 2019. DOI: 10.1186/s13019-019-0925-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.