MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1309/ajcpzsbtd2bwomvl

Медицинская библиотека · American journal of clinical pathology · 2010

Analysis of von Willebrand factor multimers by simultaneous high- and low-resolution vertical SDS-agarose gel electrophoresis and Cy5-labeled antibody high-sensitivity fluorescence detection.

Ott Helmut W, Griesmacher Andrea, Schnapka-Koepf Mirjam, Golderer Georg, Sieberer Andrea, Spannagl Michael, Scheibe Burghardt, Perkhofer Susanne, Will Kerstin, Budde Ulrich

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Analysis of von Willebrand factor (vWF) multimers allows classification of the subtypes of von Willebrand disease (vWD) in human serum and platelet lysates. A novel method for multimer analysis of vWF by 2-chamber, vertical (sodium dodecyl sulfate), agarose gel electrophoresis, designed for comparing discontinuous high- and low-resolving gels for plasma and platelets, followed by Western blotting and high-sensitivity fluorescence detection (HSFD) of cyanine (Cy)5-labeled vWF multimers is presented. HSFD shows that this method has high discriminatory power for visualization and densitometric analysis of platelets and plasma vWF multimers in various types of vWD and allows rapid classification of vWD types, to separate types 2A and 2B. The described procedures of vWF multimer analysis with high-sensitivity Cy5 fluorescence detection and direct comparison of high- and low-resolving gels for screening and detection of the complete range of high- and low-molecular vWF multimers is efficient and useful for screening, detecting, and classifying vWD subtypes and makes this method diagnostically and clinically relevant.

Для цитирования: Ott Helmut W, Griesmacher Andrea, Schnapka-Koepf Mirjam, Golderer Georg, Sieberer Andrea, Spannagl Michael, Scheibe Burghardt, Perkhofer Susanne, Will Kerstin, Budde Ulrich. Analysis of von Willebrand factor multimers by simultaneous high- and low-resolution vertical SDS-agarose gel electrophoresis and Cy5-labeled antibody high-sensitivity fluorescence detection.. American journal of clinical pathology. 2010. DOI: 10.1309/ajcpzsbtd2bwomvl.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.