MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0300891619871104

Медицинская библиотека · Tumori · 2019

Endosonographic evaluation of the mediastinum through the i-gel O2 supraglottic airway device.

Piccioni Federico, Codazzi Daniela, Paleari Maria C, Previtali Paola, Delconte Gabriele, Fumagalli Luca, Manzi Renato, Faustini Marco, Persiani Laura, Rizzi Maurilia, Sodi Federico, Masci Enzo

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Endobronchial ultrasound (EBUS) is an endoscopic diagnostic procedure combining flexible fibrobronchoscopy with ultrasound techniques; it allows transbronchial needle aspiration biopsy for the diagnosis and staging of mediastinal masses. We present our preliminary experience with the use of the i-gel O2 supraglottic airway device for management of EBUS procedures.

METHODS

An observational study on 39 patients who underwent EBUS under general anesthesia was performed. Airways were managed with i-gel O2 by anesthesiologists unfamiliar with it. Data collected included patient characteristics, i-gel O2 positioning, mechanical ventilation, procedure, and complications occurring during and after the EBUS.

RESULTS

The i-gel airway was successfully positioned during the first attempt in 34/39 cases (87.2%). No failed positioning was recorded. The EBUS scope easily passed through the i-gel in all patients and in 14 (35.6%) cases it was also inserted through the esophagus allowing the examination or fine needle aspiration of paraesophageal lymph nodes. In one case, during the EBUS procedure, the i-gel was dislocated but easily put in place again. During EBUS, air leakages were significant in 2 cases (5.1%) and minimal in 14 cases (35.9%). A brief self-solved laryngospasm and a bronchospasm during bronchoscopy were recorded. After recovery, no patients had dysphagia; mild odynophagia and pharyngodinia were referred by 2 (5.1%) and 12 (30.1%) patients, respectively.

CONCLUSIONS

The i-gel O2 airway is easy to position and manage even for anesthesiologists unfamiliar with it. This supraglottic airway device is suitable for a complete endosonographic evaluation of the mediastinum.

Для цитирования: Piccioni Federico, Codazzi Daniela, Paleari Maria C, Previtali Paola, Delconte Gabriele, Fumagalli Luca, Manzi Renato, Faustini Marco, Persiani Laura, Rizzi Maurilia, Sodi Federico, Masci Enzo. Endosonographic evaluation of the mediastinum through the i-gel O2 supraglottic airway device.. Tumori. 2019. DOI: 10.1177/0300891619871104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.