Diagnostic value and safety of color doppler ultrasound-guided transthoracic core needle biopsy of thoracic disease.
Аннотация
Objective
The aim of the present study was to explore the diagnostic value and safety of color Doppler ultrasound (US)-guided transthoracic core needle biopsy (CNB) of peripheral lung, chest wall and mediastinal lesions using automated biopsy guns.Materials and methods: We analyzed clinical and image data, histopathologic and microbiologic details and complications from 121 patients with peripheral lung, chest wall and mediastinal lesions who underwent color Doppler US-guided transthoracic CNB in Ningbo First Hospital between January 2015 and June 2018.
Results
Color Doppler US-guided transthoracic CNB performed with a freehand technique using automated biopsy guns had a sensitivity of 93.94%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 78.57%, and a diagnostic accuracy of 95.04%. Lesion size did not affect the diagnostic rate (P=0.40). No serious complications of the procedure were noted.
Conclusion
Color Doppler US-guided transthoracic CNB of peripheral lung, chest wall and mediastinal lesions is a safe and inexpensive procedure. The diagnostic accuracy of color Doppler US-guided transthoracic CNB was higher than that of color Doppler US-guided transthoracic fine needle aspiration biopsy (FNAB).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.