MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcjo.2015.04.009

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2015

Prognostic value of metal-metal contact during nasolacrimal duct probing.

Mocan Mehmet C, Gulmez Sevim Duygu, Kocabeyoglu Sibel, Irkec Murat

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the prognostic value of metal-metal contact during nasolacrimal duct (NLD) probing in patients with simple membranous versus complex congenital NLD obstructions (CNLDO).

DESIGN

Retrospective case series.

PARTICIPANTS

Infants diagnosed with CNLDO.

METHODS

Seventy-nine eyes of 70 infants with CNLDO who underwent probing were recruited. Metal-metal contact was sought during probing in every patient. CNLDO was classified into simple membranous versus complex type of obstruction. Complete resolution of epiphora, increased tear meniscus, and mucous discharge were defined as successful outcome.

RESULTS

The mean age of patients at the time of probing was 21.0 ± 8.3 (range 1-42) months. Postoperative evaluations were performed in all patients between the first and second postoperative months. Overall success rate of probing was 84.9%. A higher success rate was obtained in membranous (89.7%) versus complex (54.5%) obstructions (p = 0.01). A metal-metal contact could be established in 62 (78.5%) eyes. Treatment success was achieved in 93.5% of cases in which metal-metal contact was detected versus 52.9% of cases without metal-metal contact (p < 0.001). Among cases with metal-metal contact, a trend toward successful outcomes was observed with membranous as compared with complex obstructions (96.4% vs 71.4%, p = 0.059). Logistic regression analysis revealed the presence of metal-metal touch (odds ratio [OR] 13.3, p = 0.001) and membranous type obstruction (OR 7.7, p = 0.019) as significant factors for a successful outcome.

CONCLUSIONS

Establishment of metal-metal contact is an important prognostic sign for surgical success in both the membranous and the complex type of CNLDO.

Для цитирования: Mocan Mehmet C, Gulmez Sevim Duygu, Kocabeyoglu Sibel, Irkec Murat. Prognostic value of metal-metal contact during nasolacrimal duct probing.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2015. DOI: 10.1016/j.jcjo.2015.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.