Initial Versus Follow-up Sequential Myocardial 123I-MIBG Scintigraphy to Discriminate Parkinson Disease From Atypical Parkinsonian Syndromes.
Клиническое исследованиеСравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ryu Dong-Woo, Kim Joong-Seok, Lee Jee-Eun, Oh Yoon-Sang, Yoo Sang-Won, Yoo Ie Ryung, Lee Kwang-Soo
Аннотация
PURPOSE: Previous single-center or meta-analysis studies analyzed myocardial I-metaiodobenzylguanidine (I-MIBG) scintigraphy in a single image session and demonstrated low sensitivity and high specificity for discriminating Parkinson disease (PD) from atypical Parkinsonian syndromes (APS). This study aimed to assess diagnostic ability of myocardial I-MIBG scintigraphy at 2 phases to discriminate PD from APS.
PATIENTS AND METHODS: This hospital-based prospective study enrolled 162 PD and 26 APS patients who underwent 2 sequential I-MIBG scintigraphy evaluations. Patients were stratified into normal and decreased I-MIBG groups according to early and delayed heart-to-mediastinum (H/M) ratios. Patients with PD and normal I-MIBG uptake (initial delayed H/M ratio, ≥1.78) were considered scans without evidence of cardiac norepinephrine deficit (SWEND). Early and delayed H/M ratios on the initial and 2-year follow-up scintigraphs were studied. The diagnostic sensitivity and specificity were calculated from these confusion matrices and were analyzed according to receiver-operating characteristic curve analysis. A repeated-measures general linear model was used to investigate differences among groups over time in H/M ratio changes and washout rates.
RESULTS: Follow-up I-MIBG scintigraphy analysis had a higher diagnostic sensitivity (89.5%) than the initial imaging (72.2%). The improved sensitivity was associated with a steeper decrease in H/M ratio in the SWEND group than in the APS group.
CONCLUSIONS: Follow-up I-MIBG scintigraphy can identify cardiac sympathetic denervation and its progression in patients with PD and may be effective in discriminating PD from APS. A later decrease in myocardial I-MIBG uptake in the group with SWEND meets the Braak staging threshold hypothesis for synucleinopathy.
PATIENTS AND METHODS: This hospital-based prospective study enrolled 162 PD and 26 APS patients who underwent 2 sequential I-MIBG scintigraphy evaluations. Patients were stratified into normal and decreased I-MIBG groups according to early and delayed heart-to-mediastinum (H/M) ratios. Patients with PD and normal I-MIBG uptake (initial delayed H/M ratio, ≥1.78) were considered scans without evidence of cardiac norepinephrine deficit (SWEND). Early and delayed H/M ratios on the initial and 2-year follow-up scintigraphs were studied. The diagnostic sensitivity and specificity were calculated from these confusion matrices and were analyzed according to receiver-operating characteristic curve analysis. A repeated-measures general linear model was used to investigate differences among groups over time in H/M ratio changes and washout rates.
RESULTS: Follow-up I-MIBG scintigraphy analysis had a higher diagnostic sensitivity (89.5%) than the initial imaging (72.2%). The improved sensitivity was associated with a steeper decrease in H/M ratio in the SWEND group than in the APS group.
CONCLUSIONS: Follow-up I-MIBG scintigraphy can identify cardiac sympathetic denervation and its progression in patients with PD and may be effective in discriminating PD from APS. A later decrease in myocardial I-MIBG uptake in the group with SWEND meets the Braak staging threshold hypothesis for synucleinopathy.