Myocardial MIBG scintigraphy in genetic Parkinson's disease as a model for Lewy body disorders.
Аннотация
PURPOSE: To identify myocardial sympathetic denervation patterns suggestive of Lewy body (LB) pathology in patients with genetic and idiopathic parkinsonisms by 123I-metaiodobenzylguanidine (MIBG) scintigraphy.
METHODS
We retrospectively analysed myocardial MIBG images acquired with a dual-head gamma camera and low-energy high-resolution collimator (LEHR) in 194 patients with suspected synucleinopathy or atypical parkinsonism, including 34 with genetic Parkinson's disease (PD; 4 PARK1, 8 PARK2 and 22 PARK8), 85 with idiopathic PD (iPD), 6 with idiopathic REM sleep behaviour disorder (iRBD), 17 with dementia with LB (DLB), 40 with multiple system atrophy (MSA) and 12 with progressive supranuclear palsy (PSP), and in 45 healthy controls. We calculated heart-to-mediastinum MIBG uptake ratios (HMR) at 15 min and 4 h (HMR4H) for the LEHR and standardized medium-energy collimators, to obtain classification accuracies and optimal cut-off values for HMR using supervised classification and ROC analyses.
RESULTS
While patients with LB disorders had markedly lower HMR4HLEHR than controls (controls 1.86 ± 0.26, iPD 1.38 ± 0.29, iRBD 1.23 ± 0.09, PARK1 1.20 ± 0.09, DLB 1.17 ± 0.11; p < 0.05), for the remaining patient categories differences were smaller (PARK8 1.51 ± 0.32; p < 0.05) or not significant (MSA 1.82 ± 0.37, PSP 1.59 ± 0.23, PARK2 1.51 ± 0.30; p > 0.05). The diagnostic accuracy of HMR4HLEHR was highest in patients with LB disorders (PARK1, iPD, DLB, iRBD; 89% to 97%) and lowest in those with PARK2, PARK8, PSP and MSA (65% to 76%), with an optimal HMR4HLEHR cut-off value of 1.72 for discriminating most patients with LB disorders including iPD and 1.40 for discriminating those with aggressive LB spectrum phenotypes (DLB, PARK1 and iRBD).
CONCLUSION
Our study including patients with a wide spectrum of genetic and idiopathic parkinsonisms with different degrees of LB pathology further supports myocardial MIBG scintigraphy as an accurate tool for discriminating patients with LB spectrum disorders.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.