MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0043-1777808

Медицинская библиотека · Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2024

Long-Term Outcome and Complications after Transcondylar Screw Placement for Canine Humeral Intracondylar Fissure.

Low Daniel, Hutchings Victoria, Rutherford Scott

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to report postoperative complications and long-term outcomes following transcondylar screw placement for humeral intracondylar fissure (HIF).

STUDY

DESIGN

It was a retrospective single-centre case series. Medical records (2018-2022) were reviewed for dogs with HIF treated with transcondylar screw placement. Data collected included signalment, concurrent orthopaedic disease, partial or complete HIF, surgeon, surgical approach, surgical technique and implant type, transcondylar screw angulation, postoperative complications and outcomes. Long-term outcome was assessed with owner questionnaire, orthopaedic examination and follow-up radiography. Statistical analysis was performed to identify risk factors predisposing to a complication or a poor outcome.

RESULTS

Forty-seven dogs (57 elbows) met the inclusion criteria; long-term follow-up was available in 41 dogs (50 elbows). Minor and major medical complications were noted in seven and three elbows respectively. The total complication rate was 17.5%. Increasing age was significantly associated with a reduced risk of postoperative complications (p = 0.0051). No other risk factors were identified. A postoperative complication was not associated with a less than full outcome (p = 0.5698).

CONCLUSION

Transcondylar screw placement for HIF is associated with a low complication rate and good outcome.

Для цитирования: Low Daniel, Hutchings Victoria, Rutherford Scott. Long-Term Outcome and Complications after Transcondylar Screw Placement for Canine Humeral Intracondylar Fissure.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2024. DOI: 10.1055/s-0043-1777808.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.