MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0145561319828668

Медицинская библиотека · Ear, nose, & throat journal · 2019

Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism.

Kedarisetty Suraj, Fundakowski Christopher, Ramakrishnan Karthika, Dadparvar Simin

СтатьяПеревод пока не подготовлен

Аннотация

Localization of parathyroid adenomas for treatment of primary hyperparathyroidism can be challenging. This retrospective study compared single-photon emission computed tomography/computed tomography (SPECT/CT), 4D-CT, and US studies in detection of adenomas prior to surgery. A retrospective chart review was performed on all consecutive patients with parathyroid adenoma presenting to an urban tertiary care medical center. A total of 58 patients (45 female, 13 male) underwent surgery for parathyroid adenoma. Patients aged 28 to 80 years (mean: 58.8) with parathyroid hormone levels ranging from 42 to 424 pg/mL (mean: 168). All patients underwent preoperative SPECT/CT with 20 mCi technetium-99m MIBI (99mTc-MIBI). Fifty-three patients had additional US imaging and 14 patients had 4D-CT scans. Additionally, 34 patients had injection of 20 mCi 99mTc-MIBI on the day of surgery. Pathological correlation was performed. Comparing SPECT/CT versus 4D-CT resulted in sensitivity (77% vs 80%), specificity (71% vs 75%), and accuracy (77% vs 79%). Ultrasound was less sensitive with similar specificity (44%, 86%, respectively). Combination of SPECT/CT and 4D-CT increased sensitivity to 88%, specificity to 100%, and accuracy to 89%. Combining SPECT/CT with US resulted in sensitivity of 85%, specificity of 83%, and accuracy of 85%. Intraoperative localization substantially improved in patients who received preoperative injections. The SPECT/CT remains the best imaging modality for preoperative localization of parathyroid adenomas with high sensitivity. Combining SPECT/CT with US resulted in increased sensitivity and accuracy. For suspicion of ectopic cases or suspicion of unidentifiable adenoma with negative scintigraphy, addition of 4D-CT is recommended. Intraoperative localization and adjunctive imaging may improve surgical management of patients with hyperparathyroidism.

Для цитирования: Kedarisetty Suraj, Fundakowski Christopher, Ramakrishnan Karthika, Dadparvar Simin. Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism.. Ear, nose, & throat journal. 2019. DOI: 10.1177/0145561319828668.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.