MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resp.2021.103692

Медицинская библиотека · Respiratory physiology & neurobiology · 2021

Identifying bronchoconstriction from the ratio of diaphragm EMG to tidal volume.

He Bai-Ting, Luo Ying-Mei, Wang Li-Shuang, Chen Yong-Yi, Jolley Caroline, Steier Joerg, Moxham John, Polkey Michael L, Luo Yuanming

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A fall of ≥ 20 % in forced expiratory volume in the first second (FEV1) with a cumulative dose of histamine ≤ 7.8 μmol is considered to indicate bronchial hyperactivity, but no method exists for patients who cannot perform spirometry properly. Here we hypothesized that increases in respiratory central output measured by chest wall electromyography of the diaphragm (EMGdi-c) expressed as a function of tidal volume (EMGdi-c/VT) would have discriminative power to detect a 'positive' challenge test.

METHODS

In a physiological study EMGdi was recorded from esophageal electrode (EMGdi-e) in 16 asthma patients and 16 healthy subjects during a histamine challenge test. In a second study, EMGdi from chest wall surface electrodes (EMGdi-c) was measured during a histamine challenge in 44 asthma patients and 51 healthy subjects. VT was recorded from a digital flowmeter during both studies.

RESULTS

With histamine challenge test the change in EMGdi-e/VT in patients with asthma was significantly higher than that in healthy subjects (104.2 % ± 48.6 % vs 0.03 % ± 17.1 %, p < 0.001). Similarly there was a significant difference in the change of EMGdi-c/VT between patients with asthma and healthy subjects (90.5 % ± 75.5 % vs 2.4 % ± 21.7 %, p < 0.001). At the optimal cut-off point (29 % increase in EMGdi-c/VT), the area under the ROC curve (AUC) for detection of a positive test was 0.91 (p < 0.001) with sensitivity 86 % and specificity 92 %.

CONCLUSIONS

We conclude that EMGdi-c/VT may be used as an alternative for the assessment of bronchial hypersensitivity and airway reversibility to differentiate patients with asthma from healthy subjects.

Для цитирования: He Bai-Ting, Luo Ying-Mei, Wang Li-Shuang, Chen Yong-Yi, Jolley Caroline, Steier Joerg, Moxham John, Polkey Michael L, Luo Yuanming. Identifying bronchoconstriction from the ratio of diaphragm EMG to tidal volume.. Respiratory physiology & neurobiology. 2021. DOI: 10.1016/j.resp.2021.103692.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.